Researcher profile

Hui-Rong Qi

Hui-Rong Qi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

Development of a two-dimensional imaging GEM detector using the resistive anode readout method with $6\times6$ cells

We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ system are used to process the signals from the 49 readout channels. The detector has been tested by using the X-ray tube (8~keV). The spatial resolution of the detector is about $103.46~\mathrm{μm}$ with the detector response part about $66.41~\mathrm{μm}$. The nonlinearity of the detector is less than $1.5\%$. A quite good two dimensional imaging capability is achieved as well. The performances of the detector show the prospect of the resistive anode readout method for the large readout area imaging detectors.

preprint2013arXiv

Study on the effect of humidity and dust on leakage current of bulk micro-MEGAS detector

In this paper, the effect of humidity and dust trapped in avalanche region on leakage current of bulk micro-MEGAS detector is studied. Pyralux PC1025 layers of DuPont are introduced in bulk technique and micro-MEGAS detector with pillars of 300μm in diameter is fabricated. Leakage current is tested in air with different humidity. Silicon carbide powder and PMMA (polymethyl methacrylate) powder are added as dust to avalanche region. Leakage current with and without powder is tested in air and results are depicted in the same figure. Test results indicate that leakage current increases with both storage humidity and test humidity, and also increases when powder is introduced in avalanche region.