Researcher profile

Hongyun Qiu

Hongyun Qiu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

Performance of a focal plane detector for soft X-ray imaging spectroscopy based on back-illuminated sCMOS

Spectroscopy focusing array (SFA) and Polarimetry focusing array (PFA) are the two major payloads of enhanced X-ray Timing and Polarimetry mission (eXTP). Nested Wolter-\RNum{1} X-ray mirror module is implemented in SFA and PFA to achive high effective area. When evaluating the properties of the mirror module, the alignment of the optical axis of the X-ray mirror module and a quasi-parallel X-ray beam is a prerequisite to ensure the accuracy of the results. Hence, to assist the alignment of the X-ray mirror module, an X-ray focal plane detector is designed based on the back-illuminated scientific Complementary Metal-Oxide-Semiconductor Transistor (sCMOS) sensor GSENSE6060BSI, one of the largest detection areas, is produced by \textit{Gpixel Inc}. Then the characteristics of readout noise, dark current, and split-pixel event properties of the detector are studied with the self-developed multi-target fluorescence X-ray source in a 100 m long X-ray test facility. The energy calibration is carried out with the single-pixel event and the energy non-linearity of the detector is also obtained. Eventually, the simulation of the eXTP mirror module based on the optical model is conducted and the alignment test of the Wolter-\RNum{1} X-ray mirror module designed for \textit{EP/FXT} (Einstein Probe/Follow-up X-ray Telescope) with "Burkert test" method is shown.