Source author record

Hiroshi Karoji

Hiroshi Karoji appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

16works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

16 published item(s)

preprint2015arXiv

Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph

The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 μm to 1.26 μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 μm to 0.89 μm will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.

preprint2015arXiv

Properties of Weak Lensing Clusters Detected on Hyper Suprime-Cam 2.3 Square Degree Field

We present properties of moderately massive clusters of galaxies detected by the newly developed Hyper Suprime-Cam on the Subaru telescope using weak gravitational lensing. Eight peaks exceeding a S/N ratio of 4.5 are identified on the convergence S/N map of a 2.3 square degree field observed during the early commissioning phase of the camera. Multi-color photometric data is used to generate optically selected clusters using the CAMIRA algorithm. The optical cluster positions were correlated with the peak positions from the convergence map. All eight significant peaks have optical counterparts. The velocity dispersion of clusters are evaluated by adopting the Singular Isothemal Sphere (SIS) fit to the tangential shear profiles, yielding virial mass estimates, M500c, of the clusters which range from 2.7x10^13 to 4.4x10^14 solar mass. The number of peaks is considerably larger than the average number expected from LambdaCDM cosmology but this is not extremely unlikely if one takes the large sample variance in the small field into account. We could, however, safely argue that the peak count strongly favours the recent Planck result suggesting high sigma8$value of 0.83. The ratio of stellar mass to the dark matter halo mass shows a clear decline as the halo mass increases. If the gas mass fraction, fg, in halos is universal, as has been suggested in the literature, the observed baryon mass in stars and gas shows a possible deficit compared with the total baryon density estimated from the baryon oscillation peaks in anisotropy of the cosmic microwave background.

preprint2014arXiv

Design and performance of a F/#-conversion microlens for Prime Focus Spectrograph at Subaru Telescope

The PFS is a multi-object spectrograph fed by 2394 fibers at the prime focus of Subaru telescope. Since the F/# at the prime focus is too fast for the spectrograph, we designed a small concave-plano negative lens to be attached to the tip of each fiber that converts the telescope beam (F/2.2) to F/2.8. We optimized the lens to maximize the number of rays that can be confined inside F/2.8 while maintaining a 1.28 magnification. The microlenses are manufactured by glass molding, and an ultra-broadband AR coating (<1.5% for lambda=0.38-1.26 um) will be applied to the front surface.

preprint2014arXiv

Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru

FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.

preprint2014arXiv

Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope

The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. The metrology camera system of PFS serves as the optical encoder of the COBRA fiber motors for the configuring of fibers. The 380mm diameter aperture metrology camera will locate at the Cassegrain focus of Subaru telescope to cover the whole focal plane with one 50M pixel Canon CMOS sensor. The metrology camera is designed to provide the fiber position information within 5μm error over the 45cm focal plane. The positions of all fibers can be obtained within 1s after the exposure is finished. This enables the overall fiber configuration to be less than 2 minutes.

preprint2014arXiv

Prime Focus Instrument of Prime Focus Spectrograph for Subaru Telescope

The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding (A&G) cameras, the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy.

preprint2014arXiv

Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph

The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.

preprint2012arXiv

Detectors and cryostat design for the SuMIRe Prime Focus Spectrograph (PFS)

We describe the conceptual design of the camera cryostats, detectors, and detector readout electronics for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the Subaru telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering wavelength ranges 3800 Å - 6700 Å, 6500 Å - 10000 Å, and 9700 Å - 13000 Å, with the dispersed light being imaged in each channel by a f/1.10 vacuum Schmidt camera. In the blue and red channels a pair of Hamamatsu 2K x 4K edge-buttable CCDs with 15 um pixels are used to form a 4K x 4K array. For the IR channel, the new Teledyne 4K x 4K, 15 um pixel, mercury-cadmium-telluride sensor with substrate removed for short-wavelength response and a 1.7 um cutoff will be used. Identical detector geometry and a nearly identical optical design allow for a common cryostat design with the only notable difference being the need for a cold radiation shield in the IR camera to mitigate thermal background. This paper describes the details of the cryostat design and cooling scheme, relevant thermal considerations and analysis, and discusses the detectors and detector readout electronics.

preprint2012arXiv

FOCCoS for Subaru PFS

The Fiber Optical Cable and Connector System (FOCCoS), provides optical connection between 2400 positioners and a set of spectrographs by an optical fibers cable as part of Subaru PFS instrument. Each positioner retains one fiber entrance attached at a microlens, which is responsible for the F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. The optical fibers cable will be segmented in 3 parts at long of the way, cable A, cable B and cable C, connected by a set of multi-fibers connectors. Cable B will be permanently attached at the Subaru telescope. The first set of multi-fibers connectors will connect the cable A to the cable C from the spectrograph system at the Nasmith platform. The cable A, is an extension of a pseudo-slit device obtained with the linear disposition of the extremities of the optical fibers and fixed by epoxy at a base of composite substrate. The second set of multi-fibers connectors will connect the other extremity of cable A to the cable B, which is part of the positioner's device structure. The optical fiber under study for this project is the Polymicro FBP120170190, which has shown very encouraging results. The kind of test involves FRD measurements caused by stress induced by rotation and twist of the fiber extremity, similar conditions to those produced by positioners of the PFS instrument. The multi-fibers connector under study is produced by USCONEC Company and may connect 32 optical fibers. The tests involve throughput of light and stability after many connections and disconnections. This paper will review the general design of the FOCCoS subsystem, methods used to fabricate the devices involved and the tests results necessary to evaluate the total efficiency of the set.

preprint2012arXiv

Prime Focus Spectrograph - Subaru's future -

The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 μm to 1.3 μm will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.

preprint2012arXiv

The metrology cameras for Subaru PFS and FMOS

The Prime Focus Spectrograph (PFS) is a new multi-fiber spectrograph on Subaru telescope. PFS will cover around 1.4 degree diameter field with ~2400 fibers. To ensure precise positioning of the fibers, a metrology camera is designed to provide the fiber position information within 5 μm error. The final positioning accuracy of PFS is targeted to be better than 10 μm. The metrology camera will locate at the Cassegrain focus of Subaru telescope to cover the whole focal plane. The PFS metrology camera will also serve for the existing multi-fiber infrared spectrograph FMOS.

preprint2012arXiv

The system software development for Prime Focus Spectrogrsph on Subaru Telescope

The Prime Focus Spectrograph (PFS) is a wide field multi-fiber spectrograph using the prime focus of the Subaru telescope, which is capable of observing up to 2400 astronomical objects simultaneously. The instrument control software will manage the observation procedure communicateing with subsystems such as the fiber positioner "COBRA", the metrology camera system, and the spectrograph and camera systems. Before an exposure starts, the instrument control system needs to access to a database where target lists provided by observers are stored in advance, and accurately position fibers onto astronomical targets as requested therein. This fiber positioning will be carried out interacting with the metrology system which measures the fiber positions. In parallel, the control system can issue a command to point the telescope to the target position and to rotate the instrument rotator. Finally the telescope pointing and the rotator angle will be checked by imaging bright stars and checking their positions on the auto-guide and acquisition cameras. After the exposure finishes, the data are collected from the detector systems and are finalized as FITS files to archive with necessary information. The observation preparation software is required, given target lists and a sequence of observation, to find optimal fiber allocations with maximizing the number of guide stars. To carry out these operations efficiently, the control system will be integrated seamlessly with a database system which will store information necessary for observation execution such as fiber configurations. In this article, the conceptual system design of the observation preparation software and the instrument control software will be presented.

preprint2012arXiv

The Taiwan ECDFS Near-Infrared Survey: Very Bright End of the Luminosity Function at z>7

The primary goal of the Taiwan ECDFS Near-Infrared Survey (TENIS) is to find well screened galaxy candidates at z>7 (z' dropout) in the Extended Chandra Deep Field-South (ECDFS). To this end, TENIS provides relatively deep J and Ks data (~25.3 ABmag, 5-sigma) for an area of 0.5*0.5 degree. Leveraged with existing data at mid-infrared to optical wavelengths, this allows us to screen for the most luminous high-z objects, which are rare and thus require a survey over a large field to be found. We introduce new color selection criteria to select a z>7 sample with minimal contaminations from low-z galaxies and Galactic cool stars; to reduce confusion in the relatively low angular resolution IRAC images, we introduce a novel deconvolution method to measure the IRAC fluxes of individual sources. Illustrating perhaps the effectiveness at which we screen out interlopers, we find only one z>7 candidate, TENIS-ZD1. The candidate has a weighted z_phot of 7.8, and its colors and luminosity indicate a young (45M years old) starburst galaxy with a stellar mass of 3.2*10^10 M_sun. The result matches with the observational luminosity function analysis and the semi-analytic simulation result based on the Millennium Simulations, which may over predict the volume density for high-z massive galaxies. The existence of TENIS-ZD1, if confirmed spectroscopically to be at z>7, therefore poses a challenge to current theoretical models for how so much mass can accumulate in a galaxy at such a high redshift.

preprint2009arXiv

Reddening and Distance of the Local Group Starburst Galaxy IC 10

We estimate the reddening and distance of the nearest starburst galaxy IC 10 using deep near infrared $JHK_{S}$ photometry obtained with the Multi-Object InfraRed Camera and Spectrograph (MOIRCS) on the Subaru telescope. We estimate the foreground reddening toward IC 10 using $UBV$ photometry of IC 10 from the Local Group Survey, obtaining $E(B-V)=0.52\pm 0.04$ mag. We derive the total reddening including the internal reddening, $E(B-V)=0.98\pm 0.06$ mag, using $UBV$ photometry of early-type stars in IC 10 and comparing $JHK_{S}$ photometry of red giant branch stars in IC 10 and the SMC. Using the 2MASS point source catalog of 20 Galactic globular clusters, we derive a relation between the metallicity [Fe/H]$_{CG97}$ and the slope of the red giant branch in the $K_{S}- (J-K_{S})$ color-magnitude diagram. The mean metallicity of the red giant branch stars in IC 10 is estimated to be [Fe/H]$_{CG97}=-1.08\pm0.28$. The magnitude of the tip of the red giant branch (TRGB) of IC 10 in the $K_{S}$ band is measured to be $K_{S,TRGB}=18.28\pm0.01$. Based on the TRGB method, we estimate the distance modulus of IC 10 to be $(m-M)_{0}=24.27\pm0.03{\rm (random)}\pm0.18{\rm (systematic)}$, corresponding to the distance of $d=715\pm10\pm60$ kpc. This confirms that IC 10 is a member of the Local Group.

preprint2004arXiv

Current Performance and On-Going Improvements of the 8.2 m Subaru Telescope

An overview of the current status of the 8.2 m Subaru Telescope constructed and operated at Mauna Kea, Hawaii, by the National Astronomical Observatory of Japan is presented. The basic design concept and the verified performance of the telescope system are described. Also given are the status of the instrument package offered to the astronomical community, the status of operation, and some of the future plans. The status of the telescope reported in a number of SPIE papers as of the summer of 2002 are incorporated with some updates included as of 2004 February. However, readers are encouraged to check the most updated status of the telescope through the home page, http://subarutelescope.org/index.html, and/or the direct contact with the observatory staff.

preprint2003arXiv

Are Two z~6 Quasars Gravitationally Lensed ?

Several high-z (z > 5.7) quasars have been found in the course of Sloan Digital Sky Survey. The presence of such very high-z quasars is expected to give constraints on early structure formation. On one hand, it is suggested that these most luminous objects at high redshift are biased toward the highly magnified objects by gravitational lensing. To clarify the effect of gravitational lensing on the high-z quasars, we began the imaging survey of intervening lensing galaxies. Indeed our previous optical image showed that SDSSp J104433.04+012502.2 at z=5.74 is gravitationally magnified by a factor 2. In this paper, we report our new optical imaging of other two high-z quasars, SDSSp J103027.10+052455.0 at z=6.28 and SDSSp J130608.26+035626.3 at z=5.99. Since we find neither intervening galaxy nor counter image with i^{\prime} < 25.4-25.8 around each quasar, we conclude that they are not strongly magnified regardless that a lens galaxy is dusty.