Source author record

Hermann Kolanoski

Hermann Kolanoski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Characterization of a CdZnTe detector for a low-power CubeSat application

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between $200\;\mathrm{keV}$ and $4\;\mathrm{MeV}$, with performance comparable to the last generation of larger satellites. In order to achieve this goal, an energy resolution of few percent in full width at half maximum (FWHM) and a $3$-D spatial resolution of few millimeters for the individual detectors are needed. The severe power constraints present in small satellites require very low power read-out electronics for the detector. Our read-out is based on the VATA450.3 ASIC developed by \emph{Ideas}, with a power consumption of only $0.25\;\mathrm{mW/channel}$, which exhibits good performance in terms of dynamic range, noise and linearity. A $2.0\;\mathrm{cm} \times 2.0\;\mathrm{cm} \times 1.5\;\mathrm{cm}$ CdZnTe detector, with a custom $8 \times 8$ pixel anode structure read-out by a VATA450.3 ASIC, has been tested. A preliminary read-out system for the cathode, based on a discrete \emph{Amptek} A250F charge sensitive pre-amplifier and a DRS4 ASIC, has been implemented. An energy resolution around $3\%$ FWHM has been measured at a gamma energy of $662\;\mathrm{keV}$; at $200\;\mathrm{keV}$ the average energy resolution is $6.5\%$, decreasing to $\lesssim 2\%$ at energies above $1\;\mathrm{MeV}$. A $3$-D spatial resolution of $\approx 2\,\mathrm{mm}$ is achieved.

preprint2009arXiv

Undulator-Based Production of Polarized Positrons

Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9MeV) with circular polarization, which are then converted in a thin target to generate longitudinally polarized positrons and electrons. The experiment was carried out with a one-meter-long, 400-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) operated at 46.6GeV. Measurements of the positron polarization have been performed at five positron energies from 4.5 to 7.5MeV. In addition, the electron polarization has been determined at 6.7MeV, and the effect of operating the undulator with a ferrofluid was also investigated. To compare the measurements with expectations, detailed simulations were made with an upgraded version of Geant4 that includes the dominant polarization-dependent interactions of electrons, positrons, and photons with matter. The measurements agree with calculations, corresponding to 80% polarization for positrons near 6MeV and 90% for electrons near 7MeV.