Source author record

Heinz Amenitsch

Heinz Amenitsch appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

SAXSDOG: open software for real-time azimuthal integration of 2D scattering images

In-situ small- and wide-angle scattering experiments at synchrotrons often result in massive amounts of data within seconds only. Especially during such beamtimes, processing of the acquired data online, so without mentionable delay, is key to obtain feedback on failure or success of the experiment. We thus developed SAXSDOG, a python based environment for real-time azimuthal integration of large-area scattering-images. The software is primarily designed for dedicated data-pipelines: once a scattering image is transferred from the detector onto the storage-unit, it is automatically integrated and pre-evaluated using integral parameters within milliseconds. The control and configuration of the underlying server-based processes is done via a graphical user interface SAXSLEASH, which visualizes the resulting 1D data together with integral classifiers in real time. SAXSDOG further includes a portable 'take-home' version for users that runs on standalone computers, enabling its use in labs or at the preferred workspace.

preprint2013arXiv

Global SAXS data analysis for multilamellar vesicles: Evolution of the scattering density profile (SDP) model

We adapted the highly successful scattering density profile (SDP) model, which is used to jointly analyze small angle x-ray and neutron scattering data from unilamellar vesicles, for use with data from fully hydrated, liquid crystalline multilamellar vesicles (MLVs). By using a genetic algorithm, this new method is capable of providing high resolution structural information, as well as determining bilayer elastic bending fluctuations from standalone x-ray data. Important structural parameters, such as bilayer thickness and area per lipid were determined for a series of saturated and unsaturated lipids, as well as binary mixtures with cholesterol. Results are in good agreement with previously reported SDP data, which used both neutron and x-ray data. The addition of deuterated and non-deuterated MLV neutron data to the analysis improved lipid backbone information, but did not improve, within experimental uncertainties, the structural information regarding bilayer thickness and area per lipid.

preprint2010arXiv

Imaging with high Dynamic using an Ionization Chamber

In this work a combination of an ionization chamber with one-dimensional spatial resolution and a MicroCAT structure will be presented. The combination between gas gain operations and integrating front-end electronics yields a dynamic range as high as eight to nine orders of magnitude. Therefore this device is well suitable for medical imaging or applications such as small angle x-ray scattering, where the requirements on the dynamic of the detector are exceptional high. Basically the described detector is an ionization chamber adapted to fan beam geometry with an active area of 192 cm and a pitch of the anode strips of 150 micrometer. In the vertical direction beams as high as 10 mm can be accepted. Every read-out strip is connected to an analogue integrating electronics channel realized in a custom made VLSI chip. A MicroCAT structure utilized as a shielding grid enables frame rates as high as 10kHz. The high dynamic range observed stems from the fact that the MicroCAT enables active electron amplification in the gas. Thus a single photon resolution can be obtained for low photon fluxes even with the integrating electronics. The specialty of this device is that for each photon flux the gas amplification can be adjusted in such a fashion that the maximum DQE value is achieved.

preprint2003arXiv

Development of a two-dimensional virtual pixel X-ray imaging detector for time-resolved structure research

An interpolating two-dimensional X-ray imaging detector based on a single photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the microsecond-time domain. The prototype detector has been tested at the SAXS beamline at ELETTRA synchrotron light source with a beam energy of 8 keV to test its capabilities in the rough beamline environment. The imaging performance is examined with apertures and standard diffraction targets. Finally, the application in a time-resolved lipid temperature jump experiment is presented.