Source author record

Harish Ravi

Harish Ravi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

Permanent EDM measurement in Cs using nonlinear magneto-optic rotation

We use the technique of chopped nonlinear magneto-optic rotation (NMOR) in a room temperature $^{133}$Cs vapor cell to measure the permanent electric dipole moment (EDM) in the atom. The cell has paraffin coating on the walls to increase the relaxation time. The signature of the EDM is a shift in the Larmor precession frequency which is correlated with the application of an E field. We analyze errors in the technique, and show that the main source of systematic error is the appearance of a longitudinal B field when the E field is applied. This error can be eliminated by doing measurements on the two ground hyperfine levels. Using an E field of 2.6 kV/cm, we place an upper limit on the electron EDM of $ 2.9 \times 10^{-22} $ e-cm ($95 \%$ confidence). This limit can be increased by 7 orders-of-magnitude---and brought below the current best experimental value---with easily implementable improvements to the technique.

preprint2015arXiv

Measuring the linewidth of a stabilized diode laser

We demonstrate a straight-forward technique to measure the linewidth of a grating-stabilized diode laser system---known as an external cavity diode laser (ECDL)---by beating the output of two independent ECDLs in a Michelson interferometer, and then taking the Fourier transform of the beat signal. The measured linewidth is the sum of the linewidths of the two laser systems. Assuming that the two are equal, we find that the linewidth of each ECDL measured over a time period of 2 \textmu s is about 0.3 MHz. This narrow linewidth shows the advantage of using such systems for high-resolution spectroscopy and other experiments in atomic physics.

preprint2013arXiv

Measurement of the electronic thermal conductance channels and heat capacity of graphene at low temperature

The ability to transport energy is a fundamental property of the two-dimensional Dirac fermions in graphene. Electronic thermal transport in this system is relatively unexplored and is expected to show unique fundamental properties and to play an important role in future applications of graphene, including opto-electronics, plasmonics, and ultra-sensitive bolometry. Here we present measurements of bipolar, electron-diffusion and electron-phonon thermal conductances, and infer the electronic specific heat, with a minimum value of 10 $k_{\rm{B}}$ ($10^{-22}$ JK$^{-1}$) per square micron. We test the validity of the Wiedemann-Franz law and find the Lorenz number equals $1.32\times(π^2/3)(k_{\rm{B}}/e)^2$. The electron-phonon thermal conductance has a temperature power law $T^2$ at high doping levels, and the coupling parameter is consistent with recent theory, indicating its enhancement by impurity scattering. We demonstrate control of the thermal conductance by electrical gating and by suppressing the diffusion channel using superconducting electrodes, which sets the stage for future graphene-based single microwave photon detection.