Researcher profile

Hans Rabus

Hans Rabus contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2025arXiv

Evaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codes

This study evaluates the uncertainty in nanodosimetric calculations caused by variations in interaction cross sections within Monte Carlo Track Structure (MCTS) simulation codes. Nanodosimetry relies on accurately simulating particle interactions at the molecular scale. Different MCTS codes employ distinct physical models and datasets for electron interactions in liquid water, a surrogate for biological tissues. The paper focuses on the Ionization Cluster Size Distribution (ICSD) generated by electrons of varying energies in nanometric volumes. Seven MCTS codes were tested using their native cross sections and a common dataset derived from averaging data used in the participating codes. The results reveal significant discrepancies among the codes in ICSDs and derived biologically relevant nanodosimetric quantities such as mean ionization numbers (M1) and probabilities of obtaining two or more ionizations (F2). The largest variations were observed for low-energy electrons, where the contribution from interaction cross sections dominates the overall uncertainties. For instance, M1 values for ICSDs of electron of 20 eV can differ by around 45 % (RSD) and 34 % (RSD) was found for F2 values of ICSDs of electrons of 50 eV. Using common cross sections substantially reduced the discrepancies, suggesting that cross section datasets are the primary source of variability. Finally, estimates of deoxyribonucleic acid (DNA) damage using the PARTRAC code highlight tht cross section variations have a non-negligible impact simulated biological outcomes, particularly for double-strand breaks (DSBs) Indeed, despite the fact that many other parameters in the simulation that can greatly differ from one code to another, the different interaction cross-sections studied in this work can lead to differences in the number of DSBs calculated with the PARTRAC code of up to 15%.

preprint2022arXiv

Correlated ionisations in two spatially separated nanometric volumes in the track structure of 241Am alpha particles: comparison with Monte Carlo simulations

The production of two double strand breaks in spatially separated locations on the DNA molecule can cause the loss of a whole DNA loop, which can be of substantial length depending on the geometrical position of the two damaged sites and depends on the degree of correlation between ionisation clusters formed in sites of several nanometres in size. In the first part of this paper, nanodosimetric measurements of alpha particle tracks in 1.2 mbar H2O, 1.2 mbar C3H8 and 1.2 mbar C4H8O with the PTB ion counter nanodosimeter were reported. In this second part, the focus is on the geometrical characterisation of the two sites simulated with the nanodosimeter in the three target gases and on the comparison of the measurement results with Monte Carlo simulations. The measurements in 1.2 mbar C3H8 were simulated with a version of the track structure code PTra dedicated to modelling the PTB ion counter nanodosimeter. Further simulations were performed with Geant4-DNA for 241Am alpha particle tracks in liquid water. Simulations of the measurements and the actual measurement results are found to be in good agreement for the investigated irradiation geometries.

preprint2022arXiv

Electrical Characterization of DNA Origami Structures with PEG-PLL coating for improved robustness

Electrical conductivity of DNA has been a controversial topic since it was first proposed in 1962. Disparities in the experimental results can often be explained by differences of the ambient or experimental conditions. We report the dielectrophoretic trapping and electrical characterization of two rod-like DNA origami structures with different modifications. These were 12helix bundles, with either thiol-ends or polyA single-stranded overhangs, and 30-helix bundles, with thiol-ends and either with or without a PEG-PLL coating. The observed impedance spectra showed ohmic resistances ranging from 500 k$Ω$ to 3.4 M$Ω$ for the 30-helix bundle structures with a PEG-PLL coating. DNA origami structures without the coating were always nonconductive. Depending on the structure, destruction of the gold nanoelectrodes occurred frequently during the trapping of DNA origami nanostructures. This indicates high currents, resulting from the trapped conductive nanostructures.

preprint2022arXiv

EURADOS Working Group 6, Computational Dosimetry, a history of promoting good practice via intercomparisons and training

This paper is the editorial of a special issue of Radiation Measurements on EURADOS intercomparisons in computational dosimetry. The articles in this special issue cover complex problems in terms of geometry, particle types, energy ranges, coupled calculations and also scale, with the possibility of performing Monte Carlo calculations on micro and nano dosimetric scales now feasible. A summary of the exercises is provided in the first article of the Special Issue, which presents the findings and common conclusions from the ten articles reporting the results of the different exercises. One of these issues was the correct assessment of bone marrow dose, which prompted the inclusion of an article in this special issue explaining the ICRP-recommended method for bone marrow dosimetry.

preprint2022arXiv

Lessons learnt from the recent EURADOS intercomparisons in computational dosimetry

Organized by Working Group 6 "Computational Dosimetry" of the European Radiation Dosimetry Group (EURADOS), a group of intercomparison exercises was conducted in which participants were asked to solve predefined problems in computational dosimetry. The results of these comparisons were published in a series of articles in this virtual special issue of Radiation Measurements. This paper reviews the experience gained from the various exercises and highlights the resulting conclusions for future exercises, as well as regarding the state of the art and the need for development in terms of quality assurance for computational dosimetry techniques.

preprint2021arXiv

Is the track-event theory of cell survival internally consistent?

The "track event theory" (TET) has been developed in recent years as an alternative to the phenomenological linear-quadratic model for cell survival under exposure to ionizing radiation, particularly for heavy charged particles. The TET is based on a few simple model assumptions including the possibility to derive some of the model parameters from nanodosimetry. This work intends to carve out more clearly the basic assumptions behind the TET and to critically review the resulting mathematical model equations. It is demonstrated that the model assumptions of Poisson distribution and statistical independence of the frequency distributions of so-called one-track and two-track events follow from the Poisson distribution of the number of tracks affecting the considered target volume. It is also shown that the modified TET model equation used in the literature for consideration of repair is inconsistent with the model assumptions and requires an additional model parameter. Furthermore, the derivation of the model parameters from nanodosimetric properties of particle track structure is revealed to lead to a pure exponential dose dependence when the potentially large number of relevant nanometric target volumes inside a cell nucleus is accounted for.