Researcher profile

Hamish Silverwood

Hamish Silverwood contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

A non-parametric method for measuring the local dark matter density

We present a new method for determining the local dark matter density using kinematic data for a population of tracer stars. The Jeans equation in the $z$-direction is integrated to yield an equation that gives the velocity dispersion as a function of the total mass density, tracer density, and the tilt term that describes the coupling of vertical and radial motions. We then fit a dark matter mass profile to tracer density and velocity dispersion data to derive credible regions on the vertical dark matter density profile. Our method avoids numerical differentiation, leading to lower numerical noise, and is able to deal with the tilt term while remaining one dimensional. In this study we present the method and perform initial tests on idealised mock data. We also demonstrate the importance of dealing with the tilt term for tracers that sample $\gtrsim 1$ kpc above the disc plane. If ignored, this results in a systematic underestimation of the dark matter density.

preprint2016arXiv

A realistic assessment of the CTA sensitivity to dark matter annihilation

We estimate the sensitivity of the upcoming CTA gamma-ray telescope to DM annihilation at the Galactic centre, improving on previous analyses in a number of significant ways. First, we perform a detailed analyses of all backgrounds, including diffuse astrophysical emission for the first time in a study of this type. Second, we present a statistical framework for including systematic errors and estimate the consequent degradation in sensitivity. These errors may come from e.g. event reconstruction, Monte Carlo determination of the effective area or uncertainty in atmospheric conditions. Third, we show that performing the analysis on a set of suitably optimised regions of interest makes it possible to partially compensate for the degradation in sensitivity caused by systematics and diffuse emission. To probe dark matter with the canonical thermal annihilation cross-section, CTA systematics like non-uniform variations in acceptance over a single field of view must be kept below the 0.3% level, unless the dark matter density rises more steeply in the centre of the Galaxy than predicted by a typical Navarro-Frenk-White or Einasto profile. For a contracted $r^{-1.3}$ profile, and systematics at the 1% level, CTA can probe annihilation to $b\bar{b}$ at the canonical thermal level for dark matter masses between 100 GeV and 10 TeV.

preprint2016arXiv

The $\textit{Fermi}$-LAT gamma-ray excess at the Galactic Center in the singlet-doublet fermion dark matter model

The singlet-doublet fermion dark matter model (SDFDM) provides a good DM candidate as well as the possibility of generating neutrino masses radiatively. The search and identification of DM requires the combined effort of both indirect and direct DM detection experiments in addition to the LHC. Remarkably, an excess of GeV gamma rays from the Galactic Center (GCE) has been measured with the \textit{Fermi} Large Area Telescope (LAT) which appears to be robust with respect to changes in the diffuse galactic background modeling. Although several astrophysical explanations have been proposed, DM remains a simple and well motivated alternative. In this work, we examine the sensitivities of dark matter searches in the SDFDM scenario using $\textit{Fermi}$-LAT, CTA, IceCube/DeepCore, LUX, PICO and LHC with an emphasis on exploring the regions of the parameter space that can account for the GCE. We find that DM particles present in this model with masses close to $\sim 99$ GeV and $\sim (173-190)$ GeV annihilating predominantly into the $W^+W^-$ channel and $t\bar{t}$ channel respectively, provide an acceptable fit to the GCE while being consistent with different current experimental bounds. We also find that much of the obtained parameter space can be ruled out by future direct search experiments like LZ and XENON-1T, in case of null results by these detectors. Interestingly, we show that the most recent data by LUX is starting to probe the best fit region in the SDFDM model.

preprint2013arXiv

Complementarity of direct and indirect Dark Matter detection experiments

We investigate the prospects for reconstructing the mass, spin-independent and spin-dependent cross-sections of Dark Matter particles with a combination of future direct detection experiments such as XENON1T, and the IceCube neutrino telescope in the 86-string configuration including the DeepCore array. We quantify the degree of complementarity between the two experiments by adopting realistic values for their exposure, energy threshold and resolution. Starting from benchmark models arising from a supersymmetric model with 25 free parameters, we show that despite the stringent constraints set by the run with 79 strings, IceCube can help break the degeneracies in the Dark Matter cross-section parameter space, even in the unfortunate case where it fails to discover high energy neutrinos from the Sun. We also discuss how the reconstruction of the Dark Matter particle parameters from the combined data sets is affected by the uncertainties associated with the nuclear structure of the target material in case of spin-dependent scattering and those associated with astrophysical quantities such as the Dark Matter density and velocity distribution.

preprint2013arXiv

Sensitivity of IceCube-DeepCore to neutralino dark matter in the MSSM-25

We analyse the sensitivity of IceCube-DeepCore to annihilation of neutralino dark matter in the solar core, generated within a 25 parameter version of the minimally supersymmetric standard model (MSSM-25). We explore the 25-dimensional parameter space using scanning methods based on importance sampling and using DarkSUSY 5.0.6 to calculate observables. Our scans produced a database of 6.02 million parameter space points with neutralino dark matter consistent with the relic density implied by WMAP 7-year data, as well as with accelerator searches. We performed a model exclusion analysis upon these points using the expected capabilities of the IceCube-DeepCore Neutrino Telescope. We show that IceCube-DeepCore will be sensitive to a number of models that are not accessible to direct detection experiments such as SIMPLE, COUPP and XENON100, indirect detection using Fermi-LAT observations of dwarf spheroidal galaxies, nor to current LHC searches.

preprint2011arXiv

Design, Implementation and First Measurements with the Medipix Neutron Camera in CMS

The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux rate is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.