Source author record

H. Sui

H. Sui appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Calibration of the Super-Kamiokande Detector

Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret the digitized output of our electronics so that we can obtain physical numbers such as photon counts and their arrival times for each photomultiplier tube (PMT). In this context, we developed an in-situ procedure to determine high-voltage settings for PMTs in large detectors like SK, as well as a new method for measuring PMT quantum efficiency and gain in such a detector. The second part describes the modeling of the detector in our Monte Carlo simulation, including in particular the optical properties of its water target and their variability over time. Detailed studies on the water quality are also presented. As a result of this work, we achieved a precision sufficient for physics analysis over a wide energy range (from a few MeV to above a TeV). For example, the charge determination was understood at the 1% level, and the timing resolution was 2.1 nsec at the one-photoelectron charge level and 0.5 nsec at the 100-photoelectron charge level.

preprint2012arXiv

Search for Proton Decay into Muon plus Neutral Kaon in Super-Kamiokande I, II, and III

We have searched for proton into muon plus neutral kaon using data from a 91.7 kiloton-year exposure of Super-Kamiokande-I, a 49.2 kiloton-year exposure of Super-Kamiokande-II, and a 31.9 kiloton-year exposure of Super-Kamiokande-III. The number of candidate events in the data was consistent with the atmospheric neutrino background expectation and no evidence for proton decay in this mode was found. We set a partial lifetime lower limit of 1.6x10^33 years at the 90% confidence level.