Source author record

H. N. Chapman

H. N. Chapman appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Precise wavefront characterization of X-ray optical elements using a laboratory source

Improvements in X-ray optics critically depend on the measurement of their optical performance. The knowledge of wavefront aberrations, for example, can be used to improve the fabrication of optical elements or to design phase correctors to compensate for these errors. Nowadays, the characterization of such optics is made using intense X-ray sources such as synchrotrons. However, the limited access to these facilities can substantially slow down the development process. Improvements in the brightness of lab-based X-ray micro-sources in combination with the development of new metrology methods, and in particular ptychographic X-ray speckle tracking, enable characterization of X-ray optics in the lab with a precision and sensitivity not possible before. Here, we present a laboratory set-up that utilizes a commercially available X-ray source and can be used to characterize different types of X-ray optics. The set-up is used in our laboratory on a routine basis to characterize multilayer Laue lenses of high numerical aperture and other optical elements. This typically includes measurements of the wavefront distortions, optimum operating photon energy and focal length of the lens. To check the sensitivity and accuracy of this laboratory set-up we compared the results to those obtained at the synchrotron and saw no significant difference. To illustrate the feedback of measurements on performance, we demonstrated the correction of the phase errors of a particular multilayer Laue lens using a 3D printed compound refractive phase plate.

preprint2014arXiv

Imaging Molecular Structure through Femtosecond Photoelectron Diffraction on Aligned and Oriented Gas-Phase Molecules

This paper gives an account of our progress towards performing femtosecond time-resolved photoelectron diffraction on gas-phase molecules in a pump-probe setup combining optical lasers and an X-ray Free-Electron Laser. We present results of two experiments aimed at measuring photoelectron angular distributions of laser-aligned 1-ethynyl-4-fluorobenzene (C8H5F) and dissociating, laseraligned 1,4-dibromobenzene (C6H4Br2) molecules and discuss them in the larger context of photoelectron diffraction on gas-phase molecules. We also show how the strong nanosecond laser pulse used for adiabatically laser-aligning the molecules influences the measured electron and ion spectra and angular distributions, and discuss how this may affect the outcome of future time-resolved photoelectron diffraction experiments.

preprint2010arXiv

Cryptotomography: reconstructing 3D Fourier intensities from randomly oriented single-shot diffraction patterns

We reconstructed the 3D Fourier intensity distribution of mono-disperse prolate nano-particles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast X-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the Expansion-Maximization-Compression (EMC) framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.

preprint2010arXiv

On the feasibility of nanocrystal imaging using intense and ultrashort 1.5 Å X-ray pulses

Structural studies of biological macromolecules are severely limited by radiation damage. Traditional crystallography curbs the effects of damage by spreading damage over many copies of the molecule of interest. X-ray lasers, such as the recently built LINAC Coherent Light Source (LCLS), offer an additional opportunity for limiting damage by out-running damage processes with ultrashort and very intense X-ray pulses. Such pulses may allow the imaging of single molecules, clusters or nanoparticles, but coherent flash imaging will also open up new avenues for structural studies on nano- and micro-crystalline substances. This paper addresses the theoretical potentials and limitations of nanocrystallography with extremely intense coherent X-ray pulses. We use urea nanocrystals as a model for generic biological substances and simulate primary and secondary ionization dynamics in the crystalline sample. Our results establish conditions for ultrafast nanocrystallography diffraction experiments as a function of fluence and pulse duration.

preprint2005arXiv

Phase Aberrations in Diffraction Microscopy

In coherent X-ray diffraction microscopy the diffraction pattern generated by a sample illuminated with coherent x-rays is recorded, and a computer algorithm recovers the unmeasured phases to synthesize an image. By avoiding the use of a lens the resolution is limited, in principle, only by the largest scattering angles recorded. However, the imaging task is shifted from the experiment to the computer, and the algorithm's ability to recover meaningful images in the presence of noise and limited prior knowledge may produce aberrations in the reconstructed image. We analyze the low order aberrations produced by our phase retrieval algorithms. We present two methods to improve the accuracy and stability of reconstructions.

preprint2005arXiv

Progress in Three-Dimensional Coherent X-Ray Diffraction Imaging

The Fourier inversion of phased coherent diffraction patterns offers images without the resolution and depth-of-focus limitations of lens-based tomographic systems. We report on our recent experimental images inverted using recent developments in phase retrieval algorithms, and summarize efforts that led to these accomplishments. These include ab-initio reconstruction of a two-dimensional test pattern, infinite depth of focus image of a thick object, and its high-resolution (~10 nm resolution) three-dimensional image. Developments on the structural imaging of low density aerogel samples are discussed.