Source author record

H. Edwin Romeijn

H. Edwin Romeijn appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2010arXiv

Ultra-fast treatment plan optimization for volumetric modulated arc therapy (VMAT)

Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. We consider a cost function consisting two terms, the first which enforces a desired dose distribution while the second guarantees a smooth dose rate variation between successive gantry angles. At each iteration of the column generation method, a subproblem is first solved to generate one more deliverable MLC aperture which potentially decreases the cost function most effectively. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. The iteration of such an algorithm yields a set of deliverable apertures, as well as dose rates, at all gantry angles. Results: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation and without any couch/collimator rotations. Compared to corresponding co-planar IMRT treatment plans (9 fields for prostate cases and 5 fields for head-and-neck cases), the VMAT plans delivered much lower doses to critical structures and more conformal doses to targets. Moreover, extremely high efficiency has been achieved in our algorithm. It takes only 5~8 minutes on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18~31 seconds on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such a plan. Conclusions: We have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable and high quality treatment plans at very high efficiency.