Source author record

H. Dorrer

H. Dorrer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment

The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has been developed. The single-pixel design has been optimised to reach 100% stopping power for the radiation emitted in the Ho-163 electron capture process (besides the electron neutrino) and an energy resolution < 10 eV FWHM. We describe the design of the ECHo-1k detector chip, the fabrication steps and the characterisation at room temperature, at 4 K and at the final operation temperatures. In particular, a detailed analysis of the results from these tests allowed to define a quality check protocol based on parameters measurable at room temperature. We discuss the performance achieved with the two ECHo-1k detector chips - the first one with Ho-163 implanted in gold and the second one with Ho-163 implanted in silver - which have been used for the high statistics measurement of the ECHo-1k experiment. An average activity per pixel of 0.81 Bq and 0.71 Bq and an average energy resolution of 6.07 eV FWHM and 5.55 eV FWHM have been achieved with these two detectors, fulfilling the requirements for the first phase of the ECHo experiment.

preprint2016arXiv

Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 sigma to 2833(30stat)(15sys) eV/c2. With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.