Source author record

H. B. Coldenstrodt-Ronge

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
2topics
4close collaborators

Published work

3 publications

preprint2012arXiv

Recursive quantum detector tomography

Conventional tomographic techniques are becoming increasingly infeasible for reconstructing the operators of quantum devices of growing sophistication. We describe a novel tomographic procedure using coherent states which begins by reconstructing the diagonals of the operator, and then each successive off-diagonal in a recursive manner. Each recursion is considerably more efficient than reconstructing the operator in its entirety, and each successive recursion involves fewer parameters. We apply our technique to reconstruct the positive-operator-valued measure (POVM) corresponding to a recently developed coherent optical detector with phase sensitivity and number resolution. We discuss the effect of various parameters on the reconstruction accuracy. The results show the efficiency of the method and its robustness to experimental noise.

preprint2011arXiv

Continuous phase stabilization and active interferometer control using two modes

We present a computer-based active interferometer stabilization method that can be set to an arbitrary phase difference and does not rely on modulation of the interfering beams. The scheme utilizes two orthogonal modes propagating through the interferometer with a constant phase difference between them to extract a common phase and generate a linear feedback signal. Switching times of 50ms over a range of 0 to 6 pi radians at 632.8nm are experimentally demonstrated. The phase can be stabilized up to several days to within 3 degrees.

preprint2009arXiv

Absolute efficiency estimation of photon-number-resolving detectors using twin beams

A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.