Source author record

H. A. Contreras

H. A. Contreras appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Measurement of the Quantum Efficiency of Hamamatsu R8520 Photomultipliers at Liquid Xenon Temperature

Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to liquid xenon are being used to efficiently detect the 178 nm scintillation light in a variety of liquid xenon based particle detectors. Good knowledge of the performance of these photomultipliers under cryogenic conditions is needed to properly characterize these detectors. Here, we report on measurements of the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON Dark Matter Experiments. The quantum efficiency measurements at room temperature agree with the values provided by Hamamatsu. At low temperatures, between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative to the room temperature values.

preprint2012arXiv

Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon

We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs γ rays and the energy of the Compton-scattered γ rays was measured with a high-purity germanium (HPGe) detector placed at different scattering angles. The excellent energy resolution of the HPGe detector allows the selection of events with Compton electrons of known energy in the LXe detector. We find that the scintillation yield initially increases as the electron energy decreases from 120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The measured scintillation yield was also measured with conversion electrons from the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal calibration source. We find that the scintillation yield of the 32.1 keV transition is compatible with that obtained from the Compton coincidence measurement. On the other hand, the yield for the 9.4keV transition is much higher than that measured for a Compton electron of the same energy. We interpret the enhancement in the scintillation yield as due to the enhanced recombination rate in the presence of Xe ions left from the 32.1 keV transition, which precedes the 9.4 keV one by 220 ns, on average.