Source author record

Gregory N. McKay

Gregory N. McKay appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Lens free holographic imaging for urinary tract infection screening

Urinary tract infections (UTIs) are a common condition that can lead to serious complications including kidney injury, altered mental status, sepsis, and death. Laboratory tests such as urinalysis and urine culture are the mainstays of UTI diagnosis, whereby a urine specimen is collected and processed to reveal its cellular and chemical composition. This process requires precise specimen collection, handling infectious human waste, controlled urine storage, and timely transportation to modern laboratory equipment for analysis. Holographic lens free imaging (LFI) can measure large volumes of urine via a simple and compact optical setup, potentially enabling automatic urine analysis at the patient bedside. We introduce an LFI system capable of resolving important urine clinical biomarkers such as red blood cells, white blood cells, crystals, casts, and E. Coli in urine phantoms. This approach is sensitive to the particulate concentrations relevant for detecting several clinical urine abnormalities such as hematuria, pyuria, and bacteriuria. We show bacteria concentrations across eight orders of magnitude can be estimated by analyzing LFI measurements. LFI measurements of blood cell concentrations are relatively insensitive to changes in bacteria concentrations of over seven orders of magnitude. Lastly, LFI reveals clear differences between UTI-positive and UTI-negative urine from human patients. Together, these results show promise for LFI as a tool for urine screening, potentially offering early, point-of-care detection of UTI and other pathological processes.

preprint2021arXiv

Scattering oblique plane microscopy for in-vivo blood cell imaging

Oblique plane microscopy (OPM) enables high speed, volumetric fluorescence imaging through a single-objective geometry. While these advantages have positioned OPM as a valuable tool to probe biological questions in animal models, its potential for in vivo human imaging is largely unexplored due to its typical use with exogenous fluorescent dyes. Here we introduce a scattering-contrast oblique plane microscope (sOPM) and demonstrate label-free imaging of blood cells flowing through human capillaries in vivo. The sOPM illuminates a capillary bed in the ventral tongue with an oblique light sheet, and images side- and back- scattered signal from blood cells. By synchronizing sOPM with a conventional capillaroscope, we acquire paired widefield and axial images of blood cells flowing through a capillary loop. The widefield capillaroscope image provides absorption contrast and confirms the presence of red blood cells (RBCs), while the sOPM image may aid in determining whether optical absorption gaps (OAGs) between RBCs have cellular or acellular composition. Further, we demonstrate consequential differences between fluorescence and scattering versions of OPM by imaging the same polystyrene beads sequentially with each technique. Lastly, we substantiate in vivo observations by imaging isolated red blood cells, white blood cells, and platelets in vitro using 3D agar phantoms. These results demonstrate a promising new avenue towards in vivo blood analysis.

preprint2020arXiv

Diffuser-based computational imaging funduscope

Poor access to eye care is a major global challenge that could be ameliorated by low-cost, portable, and easy-to-use diagnostic technologies. Diffuser-based imaging has the potential to enable inexpensive, compact optical systems that can reconstruct a focused image of an object over a range of defocus errors. Here, we present a diffuser-based computational funduscope that reconstructs important clinical features of a model eye. Compared to existing diffuser-imager architectures, our system features an infinite-conjugate design by relaying the ocular lens onto the diffuser. This offers shift-invariance across a wide field-of-view (FOV) and an invariant magnification across an extended depth range. Experimentally, we demonstrate fundus image reconstruction over a 33$^{\circ}$ FOV and robustness to $\pm$4D refractive error using a constant point-spread-function. Combined with diffuser-based wavefront sensing, this technology could enable combined ocular aberrometry and funduscopic screening through a single diffuser sensor.

preprint2020arXiv

Imaging human blood cells in vivo with oblique back-illumination capillaroscopy

We present a non-invasive, label-free method of imaging blood cells flowing through human capillaries in vivo using oblique back-illumination capillaroscopy (OBC). Green light illumination allows simultaneous phase and absorption contrast, enhancing the ability to distinguish red and white blood cells. Single-sided illumination through the objective lens enables 200 Hz imaging with close illumination-detection separation and a simplified setup. Phase contrast is optimized when the illumination axis is offset from the detection axis by approximately 225 um when imaging 80 um deep in phantoms and human ventral tongue. We demonstrate high-speed imaging of individual red blood cells, white blood cells with sub-cellular detail, and platelets flowing through capillaries and vessels in human tongue. A custom pneumatic cap placed over the objective lens stabilizes the field of view, enabling longitudinal imaging of a single capillary for up to seven minutes. We present high-quality images of blood cells in individuals with Fitzpatrick skin phototypes II, IV, and VI, showing that the technique is robust to high peripheral melanin concentration. The signal quality, speed, simplicity, and robustness of this approach underscores its potential for non-invasive blood cell counting.