Researcher profile

Gordon Stacey

Gordon Stacey contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

CCAT-prime: The 850 GHz camera for Prime-Cam on FYST

The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity mapping during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be the highest frequency module in Prime-Cam and the most novel for astronomical and cosmological surveys, taking full advantage of the atmospheric transparency at the high 5600 meter CCAT-prime siting on Cerro Chajnantor. With a 1.1 deg diameter field, the 850 GHz module will deploy ~40,000 Kinetic Inductance Detectors (KIDs) with Silicon platelet feedhorn coupling (both fabricated at NIST), and will provide unprecedented broadband intensity and polarization measurement capabilities. The 850 GHz module will be key to addressing pressing astrophysical questions regarding galaxy formation, Big Bang cosmology, and star formation within our own Galaxy. We present the motivation and overall design for the module, and initial laboratory characterization.

preprint2022arXiv

CCAT-prime: The Optical Design for the Epoch of Reionization Spectrometer

The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity mapping of the 158 $μ$m [CII] line in aggregates of star-forming galaxies between redshifts of 3.5 and 8 to trace the evolution of structure in the universe during the epoch of reionization. Here we present the optical design of the module including studies of the optical quality and other key parameters at the image surface. In order to achieve the required resolving power (R$\sim$100) with the FPI, it is important to have a highly collimated beam at the Lyot stop of the system; the optimization process to achieve this goal with four lenses instead of three as used in other Prime-Cam modules is outlined. As part of the optimization, we test the effect of replacing some of the aspheric lenses with biconic lenses in this Crossed Dragone design and find that the biconic lenses tend to improve the image quality across the focal plane of the module.

preprint2020arXiv

Far-Infrared Line Diagnostics: Improving N/O Abundance Estimates for Dusty Galaxies

The Nitrogen-to-Oxygen (N/O) abundance ratio is an important diagnostic of galaxy evolution since the ratio is closely tied to the growth of metallicity and the star formation history in galaxies. Estimates for the N/O ratio are traditionally accomplished with optical lines that could suffer from extinction and excitation effects, so the N/O ratio is arguably measured better through far-infrared (far-IR) fine-structure lines. Here we show that the [N III]57$μ$m/[O III]52$μ$m line ratio, denoted $N3O3$, is a physically robust probe of N/O. This parameter is insensitive to gas temperature and only weakly dependent on electron density. Though it has a dependence on the hardness of the ionizing radiation field, we show that it is well corrected by including the [Ne III]15.5$μ$m/[Ne II]12.8$μ$m line ratio. We verify the method, and characterize its intrinsic uncertainties by comparing the results to photoionization models. We then apply our method to a sample of nearby galaxies using new observations obtained with SOFIA/FIFI-LS in combination with available Herschel/PACS data, and the results are compared with optical N/O estimates. We find evidence for a systematic offset between the far-IR and optically derived N/O ratio. We argue this is likely due to that our far-IR method is biased towards younger and denser H II regions, while the optical methods are biased towards older H II regions as well as diffuse ionized gas. This work provides a local template for studies of ISM abundance in the early Universe.