Source author record

Giulio Pellegrini

Giulio Pellegrini appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

First Results for the pLGAD Sensor for Low-Penetrating Particles

Silicon sensors are the go-to technology for high-precision sensors in particle physics. But only recently low-noise silicon sensors with internal amplification became available. The so-called Low Gain Avalanche Detector (LGAD) sensors have been developed for applications in High Energy Physics, but lack two characteristics needed for the measurement of low-energy protons (<60 keV): a thin entrance window (in the order of tens of nm) and the efficient amplification of signals created near the sensor's surface (in a depth below 1 um). In this paper we present the so-called proton Low Gain Avalanche Detector (pLGAD) sensor concept and some results from characterization of the first prototypes of the sensor. The pLGAD is specifically designed to detect low-energy protons, and other low-penetrating particles. It will have a higher detection efficiency than non-silicon technologies, and promises to be a lot cheaper and easier to operate than competing silicon technologies.

preprint2015arXiv

Design and Fabrication of an Optimum Peripheral Region for Low Gain Avalanche Detectors

Low Gain Avalanche Detectors (LGAD) represent a remarkable advance in high energy particle detection, since they provide a moderate increase (gain ~10) of the collected charge, thus leading to a notable improvement of the signal-to-noise ratio, which largely extends the possible application of Silicon detectors beyond their present working field. The optimum detection performance requires a careful implementation of the multiplication junction, in order to obtain the desired gain on the read out signal, but also a proper design of the edge termination and the peripheral region, which prevents the LGAD detectors from premature breakdown and large leakage current. This work deals with the critical technological aspects when optimising the LGAD structure. The impact of several design strategies for the device periphery is evaluated with the aid of TCAD simulations, and compared with the experimental results obtained from the first LGAD prototypes fabricated at the IMB-CNM clean room. Solutions for the peripheral region improvement are also provided.

preprint2011arXiv

Charged Particle Tracking with the Timepix ASIC

A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.