Researcher profile

Giovanni Boero

Giovanni Boero contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Single chip dynamic nuclear polarization microsystem

The integration on a single chip of the sensitivity-relevant electronics of nuclear magnetic resonance (NMR) and electron spin resonance (ESR) spectrometers is a promising approach to improve the limit of detection, especially for samples in the nanoliter and subnanoliter range. Here we demonstrate the co-integration on a single silicon chip of the front-end electronics of an NMR and an ESR detector. The excitation/detection planar spiral microcoils of the NMR and ESR detectors are concentric and interrogate the same sample volume. This combination of sensors allows to perform dynamic nuclear polarization (DNP) experiments using a single-chip integrated microsystem having an area of about 2 mm$^2$. In particular, we report $^1$H DNP-enhanced NMR experiments on liquid samples having a volume of about 1 nL performed at 10.7 GHz(ESR)/16 MHz(NMR). NMR enhancements as large as 50 are achieved on TEMPOL/H$_{2}$O solutions at room temperature. The use of state-of-the-art submicrometer integrated circuit technologies should allow the future extension of the single-chip DNP microsystem approach proposed here up the THz(ESR)/GHz(NMR) region, corresponding the strongest static magnetic fields currently available. Particularly interesting is the possibility to create arrays of such sensors for parallel DNP-enhanced NMR spectroscopy of nanoliter and subnanoliter samples.

preprint2015arXiv

Nuclear magnetic resonance spectroscopy of single subnanoliter ova

Nuclear magnetic resonance (NMR) spectroscopy is, in principle, a promising candidate to study the intracellular chemistry of single microscopic living entities. However, due to sensitivity limitations, NMR experiments were reported only on very few and relatively large single cells down to a minimum volume of 10 nl. Here we show NMR spectroscopy of single ova at volume scales (0.1 and 0.5 nl) where life development begins for a broad variety of animals, humans included. We demonstrate that the sensitivity achieved by miniaturized inductive NMR probes (few pmol of 1H nuclei in some hours at 7 T) is sufficient to observe chemical heterogeneities among subnanoliter ova of tardigrades. Such sensitivities should allow to non-invasively monitor variations of concentrated intracellular compounds, such as glutathione, in single mammalian zygotes.

preprint2009arXiv

Nano-Hall sensors with granular Co-C

We analyzed the performance of Hall sensors with different Co-C ratios, deposited directly in nano-structured form, using $Co_2(CO)_8$ gas molecules, by focused electron or ion beam induced deposition. Due to the enhanced inter-grain scattering in these granular wires, the Extraordinary Hall Effect can be increased by two orders of magnitude with respect to pure Co, up to a current sensitivity of $1 Ω/T$. We show that the best magnetic field resolution at room temperature is obtained for Co ratios between 60% and 70% and is better than $1 μT/Hz^{1/2}$. For an active area of the sensor of $200 \times 200 nm^2$, the room temperature magnetic flux resolution is $ϕ_{min} = 2\times10^{-5}ϕ_0$, in the thermal noise frequency range, i.e. above 100 kHz.