Researcher profile

Gianmarco Pinton

Gianmarco Pinton contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models

Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.

preprint2020arXiv

Quantitative sub-resolution blood velocity estimation using ultrasound localization microscopy ex-vivo and in-vivo

Super-resolution ultrasound imaging relies on the sub-wavelength localization of microbubble contrast agents. By tracking individual microbubbles, the velocity and flow within microvessels can be estimated. However, a 2D super-resolution image can only localize bubbles with sub-wavelength resolution in the imaging plane whereas the resolution in the elevation plane is limited by conventional beamwidth physics. Since ultrasound imaging integrates echoes over the elevation dimension, velocity estimates at a single location in the imaging plane include information throughout the imaging slice thickness. This slice thickness is typically a few orders or magnitude larger than the super-resolution limit. It is shown here that in order to estimate the velocity, a spatial integration over the elevation direction must be considered. This operation yields a multiplicative correction factor that compensates for the elevation integration. A correlation-based velocity estimation technique is then presented. Calibrated microtube phantom experiments are used to validate the proposed velocity estimation method and the proposed elevation integration correction factor. It is shown that velocity measurements are in agreement with theoretical predictions within the considered range of flow rates (10 to 90 $μ$L/min). Then, the proposed technique is applied to two in-vivo mouse tail experiments imaged with a low frequency human clinical transducer with human clinical concentrations of microbubbles. In the first experiment, a vein was visible with a diameter of 140 $μ$m and a peak flow velocity of 0.8 mm/s. In the second experiment, a vein was observed in the super-resolved image with a diameter of 120~$μ$m and with maximum local velocity of $\approx$~4.4~mm/s. It is shown that the parabolic flow profiles within these micro-vessels are resolvable.

preprint2020arXiv

Ultrasound imaging of the human body with three dimensional full-wave nonlinear acoustics. Part 1: simulations methods

Simulations of three dimensional ultrasound propagation in heterogeneous media are computationally intensive due to the constraints arising from the large size of the domain, which is on the order of hundreds of wavelengths, and the small size of scatterers, which are much smaller than a wavelength. Consequently, three dimensional ultrasound imaging simulations are currently based on models that simplify the propagation physics. Here the full three dimensional wave physics is simulated with finite differences to generate ultrasound images of the human body based directly on the first principles of propagation and backscattering. The Visible Human project, a 3D data set of the human body that was generated with photographs of 0.33 mm cryosections, is converted into 3D acoustical maps. A full-wave nonlinear acoustic simulation tool is used to propagate ultrasound into the liver with a 2D intercostal ultrasound array in a $93 \times 39 \times 22$ mm domain with $6\times10^8$ points. Imaging metrics, based on the beamplots, root-mean-square phase aberration, spatial coherence lengths, and contrast-to-noise ratio are used to characterize the image quality. It is shown that the harmonic image quality is better than the fundamental image quality due, in part, to a narrower beam profile. The root-mean-square estimate of aberration after propagation through the simulated body wall is shown to be low (23.4 ns), consistently with previous reports of aberration measured experimentally in a human body wall. The spatial coherence measured at the transducer surface indicates that a transducer array element size of $<0.81 λ$ would be required to fully sample the acoustic field. These simulated three dimensional ultrasound images based directly on propagation physics provide a platform to investigate the sources of image degradation in three dimensions (included in Part II).

preprint2020arXiv

Ultrasound imaging with three dimensional full-wave nonlinear acoustic simulations. Part 2: sources of image degradation in intercostal imaging

Fullwave simulations are applied to an intercostal imaging scenario to determine the sources of fundamental and harmonic image degradation with respect to aberration and reverberation. These simulations are based on Part I of this two part paper, which established the Fullwave simulation methods to generate realistic ultrasound images based directly on the first principles of wave propagation in the human body. The ultasound images are generated based on the first principles of propagation and reflection and they describe interplay between distributed aberration and reverberation clutter. Three imaging scenarios that would not be realizable in vivo are investigated in silico. First, the ribs were completely removed and replaced with fat. Then, the ribs were maintained in their anatomically correct configuration to yield a reference image. Finally the ribs were placed closer together in elevation. The propagation based B-mode images show that of these three scenarios the second, anatomically correct configuration, has the best contrast-to-noise ratio. This is due to two competing effects. First the ribs effectively apodize the fundamental and harmonic beams by 3-5 dB. This effect alone would predict an improvement in image quality. However, the B-mode image quality, measured by the contrast-to-noise ratio degrades by 8%. To explain these changes, it is shown that a second effect, multiple reverberation, must be taken into account. A point spread function analysis shows that when the ribs are placed closer together they generate significantly more reverberation clutter (by 2.4 to 2.9 dB), degrading the image quality even though the beamplot has lower sidelobes. In this intercostal imaging scenario the effects of the ribs on beam shape and reverberation are therefore in competition in terms of image quality and there is an optimal acoustic window that balances them out.