Source author record

Giancarlo Nebbia

Giancarlo Nebbia appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Toward inertial sensing with a monochromatic $ 2^3 S $ positronium beam

In this work, we discuss the possibility of inertial sensing with positronium in the $2^3 S$ metastable state for the measurement of optical dipole, relativistic and gravitational forces on a purely leptonic matter-antimatter system. Starting from the characteristics of an available $2^3 S$ beam, we estimate the time necessary to measure accelerations ranging from $\sim10^5$ $m/s^2$ to 9.1 $m/s^2$ with two different inertial sensitive devices: a classical moiré deflectometer and a Mach-Zehnder interferometer. The sensitivity of the Mach-Zehnder interferometer has been estimated to be several tens of times better than that of the moiré deflectometer, for the same measurement time.\\ Different strategies to strengthen the $2^3 S$ beam flux and to improve the sensitivity of the devices are proposed and analyzed. Among them, the most promising are reducing the divergence of the positronium beam through 2D laser Doppler cooling and coherent positronium Raman excitation from the ground state to the $2^3 S$ level. If implemented, these improvements promise to result in the time required to measure an acceleration of 9.1 $m/s^2$ of few weeks and 100 $m/s^2$ of a few hours. Different detection schemes for resolving the fringe pattern shift generated on $2^3 S$ positronium crossing the deflectometer/interferometer are also discussed.

preprint2021arXiv

A fiber detector to monitor ortho-Ps formation and decay

We describe a novel method to use a scintillating fiber detector similar to the Fast Annihilation Cryogenic Tracking (FACT) used at the antimatter experiment AEgIS to monitor the presence of ortho-positronium. A single scintillating fiber was coupled to a photomultiplier tube and irradiated by flashes of about $6\cdot10^6$ $511\,\text{keV}$ $γ$-rays produced by $\approx10\,\text{ns}$ long positron pulses. The results were used to demonstrate the ability to track the creation and annihilation of ortho-positronium atoms over time in cryogenic and highly magnetic environments by using the FACT detector as a "digital calorimeter".

preprint2020arXiv

Absolute fraction of emitted Ps determined by GEANT4 supported analysis of gamma spectra

The fraction of positronium (Ps) emitted from a surface of a germanium single crystal at high temperature is usually assumed to approach unity at zero positron implantation energy. In the experiment, however, the determination of the absolute Ps fraction is not straight forward since recording a reference spectrum with $100\,\%$ Ps formation remains demanding. We use GEANT4-simulated detector responses to $2γ$ and $3γ$ radiation sources mimicking positron and Ps annihilation inside the (coincidence) Doppler-broadening spectrometer at NEPOMUC, FRM II, in order to derive a reliable value for the Ps fraction reemitted from a Ge(100) target heated close to its melting point. Analysis of the measured spectra by fitting the simulated spectra shows an absolute value of $(72\,\pm{4})\,\%$ maximum Ps formation, contradicting the $100\,\%$ assumption.