Source author record

Gerard J. Machado

Gerard J. Machado appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Below-shot-noise capacity in phase estimation using nonlinear interferometers

Over the past decade, several schemes for imaging and sensing based on nonlinear interferometers have been proposed and demonstrated experimentally. These interferometers exhibit two main advantages. First, they enable probing a sample at a chosen wavelength while detecting light at a different wavelength with high efficiency (bicolor quantum imaging and sensing with undetected light). Second, they can show quantum-enhanced sensitivities below the shot-noise limit, potentially reaching Heisenberg-limited precision in parameter estimation. Here, we compare three quantum-imaging configurations using only easily accessible intensity-based measurements for phase estimation: a Yurke-type SU(1,1) interferometer, a Mandel-type induced-coherence interferometer, and a hybrid scheme that continuously interpolates between them. While an ideal Yurke interferometer can exhibit Heisenberg scaling, this advantage is known to be fragile under realistic detection constraints and in the presence of loss. We demonstrate that differential intensity detection in the Mandel interferometer provides the highest and most robust phase sensitivity among the considered schemes, reaching but not surpassing the shot-noise limit, even in the presence of loss. Intensity measurements in a Yurke-type configuration can achieve genuine sub-shot-noise sensitivity under balanced losses and moderate gain; however, their performance degrades in realistic high-gain regimes. Consequently, in this regime, the Mandel configuration with differential detection outperforms the Yurke-type setup and constitutes the most robust approach for phase estimation.

preprint2020arXiv

Optical Coherence Tomography with a nonlinear interferometer in the high parametric gain regime

We demonstrate optical coherence tomography based on an SU(1,1) nonlinear interferometer with high-gain parametric down-conversion. For imaging and sensing applications, this scheme promises to outperform previous experiments working at low parametric gain, since higher photon fluxes provide lower integration times for obtaining high-quality images. In this way one can avoid using single-photon detectors or CCD cameras with very high sensitivities, and standard spectrometers can be used instead. Other advantages are: higher sensitivity to small loss and amplification before detection, so that the detected light power considerably exceeds the probing one.