Researcher profile

Georg Hoffstaetter

Georg Hoffstaetter contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

CSR wake expressions with two bending magnets and simulation results for the multi-turn ERL, CBETA

This paper consists of two main parts regarding Coherent Synchrotron Radiation (CSR). The first part extends the CSR theory of two particle interaction from a system of one bending magnet to two bending magnets, where the wake can leak from the first to the second. The new theory agrees well with the established simulation code Bmad. The second part of the paper presents the CSR simulation results on CBETA, the Cornell BNL Energy-Recovery-Linac (ERL) Test Accelerator, in which the magnets are so close to each other and the new extended theory becomes important. CBETA is the first multi-turn ERL with Superconducting Radio Frequency (SRF) accelerating cavities and a Fixed Field Alternating gradient (FFA) beamline. Simulations show that CSR causes phase space dilution that becomes more significant as the bunch charge and the number of recirculation passes increase. Potential ways to mitigate the CSR effects, including adding vacuum chamber shielding and increasing bunch length, are being investigated.

preprint2015arXiv

Detection and clearing of trapped ions in the high current Cornell photoinjector

We have recently performed experiments to test the effectiveness of three ion-clearing strategies in the Cornell high intensity photoinjector: DC clearing electrodes, bunch gaps, and beam shaking. The photoinjector reaches a new regime of linac beam parameters where high CW beam currents lead to ion trapping. Therefore ion mitigation strategies must be evaluated for this machine and other similar future high current linacs. We have developed several techniques to directly measure the residual trapped ions. Our two primary indicators of successful clearing are the amount of ion current removed by a DC clearing electrode, and the absence of bremsstrahlung radiation generated by beam-ion interactions. Measurements were taken for an electron beam with an energy of 5 MeV and CW beam currents in the range of 1-20 mA. Several theoretical models have been developed to explain our data. Using them, we are able to estimate the clearing electrode voltage required for maximum ion clearing, the creation and clearing rates of the ions while employing bunch gaps, and the sinusoidal shaking frequency necessary for clearing via beam shaking. In all cases, we achieve a maximum ion clearing of at least 70 percent or higher, and in some cases our data is consistent with full ion clearing.

preprint2015arXiv

On superconducting niobium accelerating cavities fired under N2-gas exposure

The dependence of the Q-value on the RF field (Q-slope) is actively studied in various accelerator laboratories. Although remedies against this dependence have been found, the physical cause still remains obscure. A rather straightforward two-fluid model description of the Q-slope in the low and high field domains is presented with emphasis on the recently experimentally identified improvement of the Q-value by so-called "N-doping".

preprint2014arXiv

Nitrogen-Doped 9-Cell Cavity Performance in a Test Cryomodule for LCLS-II

The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q0 of 3x10^10. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nOhm/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here we report on the results of these first tests of nitrogen-doped cavities in cryomodule, which provide critical information for the LCLS-II project.

preprint2008arXiv

Extended 1D Method for Coherent Synchrotron Radiation including Shielding

Coherent Synchrotron Radiation can severely limit the performance of accelerators designed for high brightness and short bunch length. Examples include light sources based on ERLs or FELs, and bunch compressors for linear colliders. In order to better simulate Coherent Synchrotron Radiation, the established 1-dimensional formalism is extended to work at lower energies, at shorter bunch lengths, and for an arbitrary configuration of multiple bends. Wide vacuum chambers are simulated by means of vertical image charges. This formalism has been implemented in the general beam dynamics code "Bmad" and its results are here compared to analytical approximations, to numerical solutions of the Maxwell equations, and to the simulation code "elegant".