Source author record

Matthias Liepe

Matthias Liepe appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2023arXiv

The International Linear Collider: Report to Snowmass 2021

The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.

preprint2022arXiv

C$^3$ Demonstration Research and Development Plan

C$^3$ is an opportunity to realize an e$^+$e$^-$ collider for the study of the Higgs boson at $\sqrt{s} = 250$ GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C$^3$ is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced state of linear collider designs, the key system that requires technical maturation for C$^3$ is the main linac. This white paper presents the staged approach towards a facility to demonstrate C$^3$ technology with both Direct (source and main linac) and Parallel (beam delivery, damping ring, ancillary component) R&D. The white paper also includes discussion on the approach for technology industrialization, related HEP R&D activities that are enabled by C$^3$ R&D, infrastructure requirements and siting options.

preprint2022arXiv

RF Accelerator Technology R&D: Report of AF7-rf Topical Group to Snowmass 2021

Accelerator radio frequency (RF) technology has been and remains critical for modern high energy physics (HEP) experiments based on particle accelerators. Tremendous progress in advancing this technology has been achieved over the past decade in several areas highlighted in this report. These achievements and new results expected from continued R&D efforts could pave the way for upgrades of existing facilities, improvements to accelerators already under construction (e.g., PIP-II), well-developed proposals (e.g., ILC, CLIC), and/or enable concepts under development, such as FCC-ee, CEPC, C3, HELEN, multi-MW Fermilab Proton Intensity Upgrade, future Muon Colloder, etc. Advances in RF technology have impact beyond HEP on accelerators built for nuclear physics, basic energy sciences, and other areas. Recent examples of such accelerators are European XFEL, LCLS-II and LCLS-II-HE, SHINE, SNS, ESS, FRIB, and EIC. To support and enable new accelerator-based applications and even make some of them feasible, we must continue addressing their challenges via a comprehensive RF R&D program that would advance the existing RF technologies and explore the nascent ones.

preprint2020arXiv

Grain-boundary structure and segregation in Nb3Sn coatings on Nb for high-performance superconducting radiofrequency cavity applications

We report on atomic-scale analyses of grain boundary (GB) structures and segregation in Nb3Sn coatings on Nb, prepared by the vapor-diffusion process, for superconducting radiofrequency (SRF) cavity applications, utilizing atom-probe tomography, high-resolution scanning transmission electron-microscopy and first-principles calculations. We demonstrate that the chemical composition of Nb3Sn GBs is correlated strongly with the diffusion of Sn and Nb at GBs during the coating process. In a sample coated with a relatively large Sn flux, we observe an interfacial width of Sn segregation at a GB of ~3 nm, with a maximum concentration of ~35 at.%. After post-annealing at 1100 oC for 3 h, the Sn segregated at GBs disappears and Nb segregation is observed subsequently at GBs, indicating that Nb diffused into the Nb3Sn GBs from the Nb substrate. It is also demonstrated that the amount of Sn segregation in a Nb3Sn coating can be controlled by: (i) Sn flux; and (ii) the temperatures of the Nb substrates and Sn source, which may affect the overall kinetics including GB diffusion of Sn and Nb. An investigation of the correlation between the chemical compositions of GBs and Nb3Sn SRF cavity performance reveals that the Nb3Sn SRF cavities with the best performance (high-quality factors at high accelerating electric-field gradients) do not exhibit Sn segregation at GBs. Our results suggest that the chemical compositions of GBs in Nb3Sn coatings for SRF cavities can be controlled by GB engineering and can be utilized to optimize fabrication of high-quality Nb3Sn coatings for SRF cavities.

preprint2020arXiv

Stable CW Operation of Nb$_3$Sn SRF Cavity at 10 MV/m using Conduction Cooling

Superconducting radio-frequency (SRF) accelerating cavities are a promising technology for compact, high-power, MeV-scale accelerators, providing continuous beam operation for a wide range of potential applications in industry, medicine, national security, and science. However, SRF cavities have traditionally been cooled using complex and expensive cryogenic infrastructure, which has been a significant obstacle in employing this powerful technology in small-scale systems. With the recent progress on high-performance Nb$_3$Sn-coated SRF cavities and the introduction of cryocoolers, which can provide turn-key style conduction cooling below 4.2 K, this barrier can now be overcome. At Cornell University, we have developed a prototype setup that utilizes a commercial cryocooler to provide the necessary cooling for operation of a 2.6 GHz Nb$_3$Sn-coated SRF cavity. We have now demonstrated first stable operation in continuous mode at accelerating fields up to 10 MV/m with a quality factor of Q$_0$ = 4x10$^9$, thereby achieving an important milestone in making turn-key SRF a reality.

preprint2015arXiv

Analysis of Nb3Sn surface layers for superconducting RF cavity applications

We present an analysis of the Nb3Sn surface layers grown on a bulk niobium (Nb) coupon prepared at the same time and by the same vapor diffusion process used to make Nb3Sn coatings on 1.3 GHz cavities. Tunneling spectroscopy reveals a well-developed, homogeneous superconducting density of states at the surface with a gap value distribution centered around 2.7 meV and superconducting critical temperature (Tc) up to 16.3 K. Scanning Electron microscopy (STEM) performed on cross section of the sample's surface region shows a 2 microns thick Nb3Sn surface layer. The elemental composition map exhibits a Nb over Sn ratio of 3 and reveals the presence of buried sub-stoichiometric regions that have a ratio f 5. Synchrotron x-ray diffraction experiments indicate a polycrystalline Nb3Sn film and confirm the presence of Nb rich regions that occupy about a third of the coating volume. These low Tc regions could play an important role in the dissipation mechanism occurring during RF tests of Nb3Sn-coated cavities and open the way for further improving a very promising alternative to pure Nb cavities for particle accelerators.

preprint2015arXiv

On superconducting niobium accelerating cavities fired under N2-gas exposure

The dependence of the Q-value on the RF field (Q-slope) is actively studied in various accelerator laboratories. Although remedies against this dependence have been found, the physical cause still remains obscure. A rather straightforward two-fluid model description of the Q-slope in the low and high field domains is presented with emphasis on the recently experimentally identified improvement of the Q-value by so-called "N-doping".

preprint2015arXiv

Sensitivity of Niobium Superconducting Cavities to Trapped Magnetic Flux Dissipation

Future particle accelerators such as the the SLAC ``Linac Coherent Light Source-II'' (LCLS-II) and the proposed Cornell Energy Recovery Linac (ERL) require hundreds of superconducting radio-frequency (SRF) cavities operating in continuous wave (CW) mode. In order to achieve economic feasibility of projects such as these, the cavities must achieve a very high intrinsic quality factor ($Q_0$) to keep cryogenic losses within feasible limits. To reach these high $Q_0$'s in the case of LCLS-II, nitrogen-doping has been proposed as a cavity preparation technique. When dealing with $Q_0$'s greater than 1\e{10}, the effects of ambient magnetic field on $Q_0$ become significant. Here we show that the sensitivity to RF losses from trapped magnetic field in a cavity's walls is strongly dependent on the cavity preparation. Specifically, standard electropolished and 120$^\circ$C baked cavities show a residual resistance sensitivity to trapped magnetic flux of $\sim0.6$ and $\sim0.8$ n$Ω$/mG trapped, respectively, while nitrogen-doped cavities show a sensitivity of $\sim$ 1 to 5 n$Ω$/mG trapped. We show that this difference in sensitivities is directly related to the mean free path of the RF surface layer of the niobium: shorter mean free paths lead to less residual resistance sensitivity to trapped magnetic flux in the dirty limit ($\ell<<ξ_0$) while longer mean free paths lead to lower sensitivity in the clean limit ($\ell>>ξ_0$). These experimental results are also shown to have good agreement with recent theoretical predictions for pinned vortex lines oscillating in RF fields.

preprint2014arXiv

Nitrogen-Doped 9-Cell Cavity Performance in a Test Cryomodule for LCLS-II

The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q0 of 3x10^10. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nOhm/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here we report on the results of these first tests of nitrogen-doped cavities in cryomodule, which provide critical information for the LCLS-II project.