Subnatural linewidth using electromagnetically induced transparency in Doppler-broadened vapor
We obtain subnatural linewidth (i.e. $<Γ$) for probe absorption in room-temperature Rb vapor using electromagnetically induced transparency (EIT) in a $Λ$ system. For stationary atoms, the EIT dip for a resonant control laser is as wide as the control Rabi frequency $Ω_c$. But in thermal vapor, the moving atoms fill the transparency band so that the final EIT dip remains subnatural even when $Ω_c > Γ$. We observe linewidths as small as $Γ/7$ in the $D_2$ line of Rb.