Source author record

G. M. Marshall

G. M. Marshall appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

12works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2020arXiv

Study of muonium emission from laser-ablated silica aerogel

The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some extreme conditions. The measured emission rate tends to be higher for larger fractions of ablation opening and for shallower depths. More than a few ablation structures reach the emission rates similar to the highest achieved in the past measurements. The emission rate is found to be stable at least for a couple of days. Measurements of spin precession amplitudes for the produced muonium atoms and remaining muons in a magnetic field determine a muonium formation fraction of $(65.5 \pm 1.8)$%. The precession of the polarized muonium atoms is also observed clearly in vacuum. A projection of the emission rates measured at TRIUMF to the corresponding rates at J-PARC is demonstrated taking the different beam condition into account reasonably.

preprint2019arXiv

Charged particle spectra from $μ^{-}$ capture on Al

Published data on the emission of charged particles following nuclear muon capture are extremely limited. In addition to its interest as a probe of the nuclear response, these data are important for the design of some current searches for lepton flavor violation. This work presents momentum spectra of protons and deuterons following $μ^{-}$ capture in aluminum. It is the first measurement of a muon capture process performed with a tracking spectrometer. A precision of better than 10% over the momentum range of 100--190 MeV/c for protons is obtained; for deuterons of 145--250 MeV/c the precision is better than 20%. The observed partial yield of protons with emission momenta above 80 MeV/c (kinetic energy 3.4 MeV) is $0.0322\pm0.0007(\text{stat})\pm0.0022(\text{syst})$ per capture, and for deuterons above 130 MeV/c (4.5 MeV) it is $0.0122\pm0.0009(\text{stat})\pm0.0006(\text{syst})$. Extrapolating to total yields gives $0.045\pm0.001(\text{stat})\pm0.003(\text{syst}) \pm 0.001(\text{extrapolation})$ per capture for protons and $0.018\pm0.001(\text{stat})\pm0.001(\text{syst})\pm 0.002(\text{extrapolation})$ for deuterons, which are the most precise measurements of these quantities to date.

preprint2015arXiv

A search for two body muon decay signals

Lepton family number violation is tested by searching for $μ^+\to e^+X^0$ decays among the 5.8$\times 10^8$ positive muon decay events analyzed by the TWIST collaboration. Limits are set on the production of both massless and massive $X^0$ bosons. The large angular acceptance of this experiment allows limits to be placed on anisotropic $μ^+\to e^+X^0$ decays, which can arise from interactions violating both lepton flavor and parity conservation. Branching ratio limits of order $10^{-5}$ are obtained for bosons with masses of 13 - 80 MeV/c$^2$ and with different decay asymmetries. For bosons with masses less than 13 MeV/c$^{2}$ the asymmetry dependence is much stronger and the 90% limit on the branching ratio varies up to $5.8 \times 10^{-5}$. This is the first study that explicitly evaluates the limits for anisotropic two body muon decays.

preprint2013arXiv

Measurement of muonium emission from silica aerogel

Emission of muonium ($μ^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expected from a diffusion process, while small deviations from a simple room-temperature thermal diffusion model are identified. The parameters of the diffusion process are deduced from the observed yields.

preprint2012arXiv

Precision muon decay measurements and improved constraints on the weak interaction

The TWIST Collaboration has completed its measurement of the three muon decay parameters ρ, δ, and P_μξ. This paper describes our determination of ρ, which governs the shape of the overall momentum spectrum, and δ, which controls the momentum dependence of the parity-violating decay asymmetry. The results are ρ=0.74977\pm 0.00012(stat.)\pm 0.00023(syst.) and δ= 0.75049\pm 0.00021(stat.)\pm 0.00027(syst.). These are consistent with the value of 3/4 given for both parameters in the standard model, and each is over a factor of 10 more precise than the measurements published prior to TWIST. Our final results on ρ, δ, and P_μξhave been incorporated into a new global analysis of all available muon decay data, resulting in improved model-independent constraints on the possible weak interactions of right-handed particles.

preprint2011arXiv

Longitudinal muon spin relaxation in high purity aluminum and silver

The time dependence of muon spin relaxation has been measured in high purity aluminum and silver samples in a longitudinal 2 T magnetic field at room temperature, using time-differential \musr. For times greater than 10 ns, the shape fits well to a single exponential with relaxation rates of $λ_{\textrm{Al}} = 1.3 \pm 0.2\,(\textrm{stat.}) \pm 0.3\,(\textrm{syst.})\,\pms$ and $λ_{\textrm{Ag}} = 1.0 \pm 0.2\,(\textrm{stat.}) \pm 0.2\,(\textrm{syst.})\,\pms$.

preprint2011arXiv

Precise measurement of parity violation in polarized muon decay

We present a new high precision measurement of parity violation in the weak interaction, using polarized muon decay. The TWIST collaboration has measured $P_μ^πξ$, where $P_μ^π$ is the polarization of the muon in pion decay and $ξ$ describes the intrinsic asymmetry in muon decay. We find $P_μ^πξ= 1.00084 \pm 0.00029\,(\textrm{stat.})_{-0.00063}^{+0.00165}\,(\textrm{syst.})$, in good agreement with the standard model prediction of $P_μ^π=ξ=1$. Our result is a factor of 7 more precise than the pre-TWIST value, setting new limits in left-right symmetric electroweak extensions to the standard model.

preprint2010arXiv

New Experimental Constraints for the Standard Model from Muon Decay

The TWIST Collaboration has completed a new measurement of the energy-angle spectrum of positrons from the decay of highly polarized muons. A simultaneous measurement of the muon decay parameters ρ, δ, and (P_μ)ξ tests the Standard Model (SM) in a purely leptonic process and provides improved limits for relevant extensions to the SM. Specifically, for the generalized left-right symmetric model |(g_R/g_L)ζ|<0.020 and (g_L/g_R)m_2> 578 GeV/c^2, both 90% C.L.

preprint2006arXiv

Measurement of P_{mu}xi in Polarized Muon Decay

The quantity P_{mu}^{pi}xi, where xi is one of the muon decay parameters and $P_μ^π$ is the degree of muon polarization in pion decay, has been measured. The value P_{mu}^{pi}xi = 1.0003 +- 0.0006 stat. +- 0.0038 syst. was obtained. This result agrees with previous measurements but is over a factor of two more precise. It also agrees with the Standard Model prediction for P_{mu}^{pi}xi and thus leads to restrictions on left-right symmetric models.

preprint1996arXiv

Characterization of Solidified Gas Thin Film Targets via Alpha Particle Energy Loss

A method is reported for measuring the thickness and uniformity of thin films of solidified gas targets. The energy of alpha particles traversing the film is measured and the energy loss is converted to thickness using the stopping power. The uniformity is determined by measuring the thickness at different positions with an array of sources. Monte Carlo simulations have been performed to study the film deposition mechanism. Thickness calibrations for a TRIUMF solid hydrogen target system are presented.