Source author record

G. Galeazzi

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
4topics
4close collaborators

Published work

3 publications

preprint2020arXiv

Detection & imaging with Leak Microstructures

Results obtained with a new very compact detector for imaging with a matrix of Leak Microstructures (LM)are reported. Spatial linearity and spatial resolution obtained by scanning as well as the detection of alpha particles with 100% efficiency, when compared with a silicon detector, are stressed. Preliminary results recently obtained in detecting single electrons emitted by heated filament (Ec < 1 eV) at 1-3 mbar of propane are reported.

preprint2011arXiv

A battery-operated, stabilized, high-energy pulsed electron gun for the production of rare gas excimers

We report on the design of a new type of electron gun to be used for experiments of infrared emission spectroscopy of rare gas excimers. It is based on a filament heated by means of a pack of rechargeable batteries floated atop the high-voltage power supply. The filament current is controlled by a feedback circuit including a superluminescent diode decoupled from the high voltage by means of an optical fiber. Our experiment requires that the charge injection is pulsed and constant and stable in time. This electron gun can deliver several tens of nC per pulse of electrons of energy up to 100 100\,keV into the sample cell. This new design eliminates ripples in the emission current and ensures up to 12 hrs of stable performance.

preprint2011arXiv

Testing the neutrality of matter by acoustic means in a spherical resonator

New measurements to test the neutrality of matter by acoustic means are reported. The apparatus is based on a spherical capacitor filled with gaseous SF6_6 excited by an oscillating electric field. The apparatus has been calibrated measuring the electric polarizability. Assuming charge conservation in the ββ decay of the neutron, the experiment gives a limit of εp-e≲1⋅10−21ε_\text{p-e}\lesssim1\cdot10^{-21} for the electron-proton charge difference, the same limit holding for the charge of the neutron. Previous measurements are critically reviewed and found incorrect: the present result is the best limit obtained with this technique.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.