Source author record

G. Broudin-Bay

G. Broudin-Bay appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2011arXiv

Measurement of the Double Beta Decay Half-life of 130Te with the NEMO-3 Detector

This Letter reports results from the NEMO-3 experiment based on an exposure of 1275 days with 661g of 130Te in the form of enriched and natural tellurium foils. The double beta decay rate of 130Te is found to be greater than zero with a significance of 7.7 standard deviations and the half-life is measured to be T1/2 = (7.0 +/- 0.9(stat) +/- 1.1(syst)) x 10^{20} yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.

preprint2010arXiv

Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.

preprint2010arXiv

Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in $^{208}$Tl. After more than one year of background measurement, a surface activity of the scintillators of $\mathcal{A}$($^{208}$Tl) $=$ 1.5 $μ$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo detector having 12 m$^2$ of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of $\mathcal{A}$($^{208}$Tl) $<$ 2 $μ$Bq/kg (90% C.L.) with a six month measurement.

preprint2010arXiv

Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors

We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.