Researcher profile

G. Blazey

G. Blazey contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
13works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2016arXiv

A New Proton CT Scanner

The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm$^2$, for imaging an adult head phantom and reconstructing more accurate RSP values.

preprint2016arXiv

Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

preprint2015arXiv

Development of a proton Computed Tomography Detector System

Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

preprint2013arXiv

Combination of CDF and D0 W-Boson Mass Measurements

We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to $2.2 \mathrm{fb}^{-1}$ of integrated luminosity, and a D0 measurement in the electron channel using data corresponding to $4.3 \mathrm{fb}^{-1}$ of integrated luminosity. The resulting Tevatron average for the mass of the $W$ boson is $\MW = 80\,387 \pm 16 \text{MeV}$. Including measurements obtained in electron-positron collisions at LEP yields the most precise value of $\MW = 80\,385 \pm 15 \text{MeV}$.

preprint2012arXiv

Combination of CDF and D0 measurements of the W boson helicity in top quark decays

We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7 - 5.4 fb^-1 of ppbar collisions collected during Run II of the Fermilab Tevatron Collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f0) and right-handed (f+) helicities, we find f0 = 0.722 \pm 0.081 [\pm 0.062 (stat.) \pm 0.052 (syst.)] and f+ = -0.033 \pm 0.046 [\pm 0.034 (stat.) \pm 0.031 (syst.)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f0 = 0.682 \pm 0.057 [\pm 0.035 (stat.) \pm 0.046 (syst.)] and f+ = -0.015\pm0.035 [\pm 0.018 (stat.) \pm 0.030 (syst.)]. The results are consistent with standard model expectations.

preprint2012arXiv

Combination of the top-quark mass measurements from the Tevatron collider

The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a $W$ boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and {\dzero} collaborations have measured the top quark's mass in different final states for integrated luminosities of up to 5.8 fb$^{-1}$. This paper reports on a combination of these measurements that results in a more precise value of the mass than any individual decay channel can provide. It describes the treatment of the systematic uncertainties and their correlations. The mass value determined is $173.18 \pm 0.56 \thinspace ({\rm stat}) \pm 0.75 \thinspace ({\rm syst})$ GeV or $173.18 \pm 0.94$ GeV, which has a precision of $\pm 0.54%$, making this the most precise determination of the top quark mass.

preprint2012arXiv

Measurement of the differential cross section dσ/dt in elastic $p\bar{p}$ scattering at sqrt(s)=1.96 TeV

We present a measurement of the elastic differential cross section $dσ(p\bar{p}\rightarrow p\bar{p})/dt$ as a function of the four-momentum-transfer squared t. The data sample corresponds to an integrated luminosity of $\approx 31 nb^{-1}$ collected with the D0 detector using dedicated Tevatron $p\bar{p} $ Collider operating conditions at sqrt(s) = 1.96 TeV and covers the range $0.26 <|t|< 1.2 GeV^2$. For $|t|<0.6 GeV^2$, dσ/dt is described by an exponential function of the form $Ae^{-b|t|}$ with a slope parameter $ b = 16.86 \pm 0.10(stat) \pm 0.20(syst) GeV^{-2}$. A change in slope is observed at $|t| \approx 0.6 GeV^2$, followed by a more gradual |t| dependence with increasing values of |t|.

preprint2012arXiv

Measurement of the W boson helicity in top quark decays using 5.4 fb^-1 of ppbar collision data

We present a measurement of the helicity of the W boson produced in top quark decays using ttbar decays in the l+jets and dilepton final states selected from a sample of 5.4 fb^-1 of collisions recorded using the D0 detector at the Fermilab Tevatron ppbar collider. We measure the fractions of longitudinal and right-handed W bosons to be f_0 = 0.669 +- 0.102 [ +- 0.078 (stat.) +- 0.065 (syst.)] and f_+ = 0.023 +- 0.053 [+- 0.041 (stat.) +- 0.034 (syst.)], respectively. This result is consistent at the 98% level with the standard model. A measurement with f_0 fixed to the value from the standard model yields f_+ = 0.010 +- 0.037 [+- 0.022 (stat.) +- 0.030 (syst.) ].

preprint2012arXiv

Search for pair production of the scalar top quark in muon+tau final states

We present a search for the pair production of scalar top quarks ($\tilde{t}_{1}$), the lightest supersymmetric partners of the top quarks, in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using data corresponding to an integrated luminosity of {7.3 $fb^{-1}$} collected with the \dzero experiment at the Fermilab Tevatron Collider. Each scalar top quark is assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$). We investigate final states arising from $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}μτ\tildeν \tildeν$ and $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}ττ\tildeν \tildeν$. With no significant excess of events observed above the background expected from the standard model, we set exclusion limits on this production process in the ($m_{\tilde{t}_{1}}$,$m_{\tildeν}$) plane.

preprint2011arXiv

Precise measurement of the top quark mass in the dilepton channel at D0

We measure the top quark mass (mt) in ppbar collisions at a center of mass energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events, where l denotes an electron, a muon, or a tau that decays leptonically. The data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0 detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat) +- 2.4(syst) GeV, which is in agreement with the current world average mt = 173.3 +- 1.1 GeV. This is currently the most precise measurement of mt in the dilepton channel.

preprint2010arXiv

Determination of the width of the top quark

We extract the total width of the top quark, Gamma_t, from the partial decay width Gamma(t -> W b) measured using the t-channel cross section for single top quark production and from the branching fraction B(t -> W b) measured in ttbar events using up to 2.3 fb^-1 of integrated luminosity collected by the D0 Collaboration at the Tevatron ppbar Collider. The result is Gamma_t = 1.99 +0.69 -0.55 GeV, which translates to a top-quark lifetime of tau_t = (3.3 +1.3 -0.9) x 10^-25 s. Assuming a high mass fourth generation b&#39; quark and unitarity of the four-generation quark-mixing matrix, we set the first upper limit on |Vtb&#39;| < 0.63 at 95% C.L.

preprint2010arXiv

Search for pair production of the scalar top quark in the electron-muon final state

We report the result of a search for the pair production of the lightest supersymmetric partner of the top quark ($\tilde{t}_1$) in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider corresponding to an integrated luminosity of 5.4 fb$^{-1}$. The scalar top quarks are assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$), and the search is performed in the electron plus muon final state. No significant excess of events above the standard model prediction is detected, and improved exclusion limits at the 95% C.L. are set in the the ($M_{\tilde{t}_1}$,$M_{\tildeν}$) mass plane.