Researcher profile

G. B. Kim

G. B. Kim contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

Direct measurement of the $^7$Be $L/K$ capture ratio in Ta-based superconducting tunnel junctions

We report a high-statistics measurement of the $L/K$ orbital electron capture (EC) ratio in $^7$Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction (STJ) radiation detector that was used to identify the signals from different decay channels. The measured $L/K$ capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus, and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. This is the first experiment that uses STJs for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

preprint2020arXiv

Limits on the Existence of sub-MeV Sterile Neutrinos from the Decay of $^7$Be in Superconducting Quantum Sensors

Sterile neutrinos are natural extensions to the standard model of particle physics and provide a possible portal to the dark sector. We report a new search for the existence of sub-MeV sterile neutrinos using the decay-momentum reconstruction technique in the decay of $^7$Be. The experiment measures the total energy of the $^7$Li daughter atom from the electron capture decay of $^7$Be implanted into sensitive superconducting tunnel junction (STJ) quantum sensors. This first experiment presents data from a single STJ operated at a low count rate for a net total of 28 days, and provides exclusion limits on sterile neutrinos in the mass range from 100 to 850 keV that improve upon previous work by up to an order of magnitude.

preprint2015arXiv

Measurement of the quenching and channeling effects in a CsI crystal used for a WIMP search

We have studied channeling effects in a Cesium Iodide (CsI) crystal that is similar in composition to the ones being used in a search for Weakly Interacting Massive Particles (WIMPs) dark matter candidates, and measured its energy-dependent quenching factor, the relative scintillation yield for electron and nuclear recoils. The experimental results are reproduced with a GEANT4 simulation that includes a model of the scintillation efficiency as a function of electronic stopping power. We present the measured and simulated quenching factors and the estimated effects of channeling.

preprint2014arXiv

Neutron calibration facility with an Am-Be source for pulse shape discrimination measurement of CsI(Tl) crystals

We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to nuclear recoils induced by neutrons from the Am-Be source and comparing them with the response to electron recoils produced by Compton scattering of 662-keV $γ$-rays from a $^{137}$Cs source. The measured results on pulse shape discrimination (PSD) between nuclear- and electron-recoil events are quantified in terms of quality factors. A comparison with similar result from a neutron reactor demonstrate the feasibility of performing calibrations of PSD measurements using neutrons from a Am-Be source.

preprint2014arXiv

Search for Low-Mass Dark Matter with CsI(Tl) Crystal Detectors

We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting massive particles(WIMPs), strong candidates of dark matter particles,using the low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS) experiment. With a total data exposure of 24,324.3kg$\cdot$days,we search for WIMP interaction signals produced by nuclei recoiling from WIMP-nuclear elastic scattering with visible energies between 2 and 4keV. The observed energy distribution of candidate events is consistent with null signals, and upper limits of the WIMP-proton spin-independent interaction are set with a 90% confidence level. The observed limit rejects most of the low mass region of parameter space favored by the DAMA annual modulation signal.

preprint2014arXiv

Thermal Model and Optimization of a Large Crystal Detector using a Metallic Magnetic Calorimeter

We established a simple thermal model of the heat flow in a large crystal detector designed for a neutrinoless double beta decay experiment. The detector is composed of a CaMoO$_{4}$ crystal and a metallic magnetic calorimeter (MMC). The thermal connection between the absorber and the sensor consists of a gold film evaporated on the crystal surface and gold bonding wires attached to this film and the MMC sensor. The model describes athermal and thermal processes of heat flow to the gold film. A successive experiment based on optimization calculations of the area and thickness of the gold film showed a significant improvement in the size and rise-time of the measured signals.