Source author record

G. Atoian

G. Atoian appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

On the possibility of measuring the polarization of a ${}^3\rm{He}$ beam at EIC by the HJET polarimeter

The requirements for hadron polarimetry at the future Electron Ion Collider (EIC) include measurements of the absolute helion (${}^3\text{He}$, $h$) beam polarization with systematic uncertainties better than $σ^\text{syst}_P/P\lesssim1\%$. Here, we consider a possibility to utilize the Polarized Atomic Hydrogen Gas Jet Target (HJET) for precision measurement of polarization of the $\sim$100 GeV/n helion beam. HJET, which serves to determine absolute proton beam polarization at the Relativistic Heavy Ion Collider, provides the accuracy of about $δ^\text{syst}P/P\sim0.5\%$. Potential problems for adapting the HJET method for the EIC helion beam include (i) necessity to know the ratio of $p^\uparrow{h}$ and $h^\uparrow{p}$ analyzing powers $A_\text{N}^{ph}(t)/A_\text{N}^{hp}(t)$ with high precision, ({ii) possible beam ${}^3\text{He}$ breakup, and (iii) operation in a 10 ns bunch spacing beam. Preliminary results of an analysis discussed here indicate that the listed problems can be overcome and the helion beam absolute polarization can be measured by HJET with the required accuracy.

preprint2020arXiv

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 ($E_\text{beam}\!=\!100~\text{GeV}$) and 17 ($255~\text{GeV}$). For a typical 8 hour RHIC store, the measured proton beam average polarization was about $P_\text{beam}\!\sim\!55\pm2.0_\text{stat}\pm0.3_\text{syst}\%$. The elastic $\mathit{pp}$ analyzing power, $A_\text{N}(t)\!\sim\!0.04$, was determined with a precision of about $|δA_\text{N}(t)|\!\sim\!0.0002$ in the momentum transfer squared range $0.001\!<\!-t\!<\!0.020\,\text{GeV}^2$. In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

preprint2009arXiv

The FP420 R&D Project: Higgs and New Physics with forward protons at the LHC

We present the FP420 R&D project, which has been studying the key aspects of the development and installation of a silicon tracker and fast-timing detectors in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS experiments. These detectors would measure precisely very forward protons in conjunction with the corresponding central detectors as a means to study Standard Model (SM) physics, and to search for and characterise New Physics signals. This report includes a detailed description of the physics case for the detector and, in particular, for the measurement of Central Exclusive Production, pp --> p + phi + p, in which the outgoing protons remain intact and the central system phi may be a single particle such as a SM or MSSM Higgs boson. Other physics topics discussed are gamma-gamma and gamma-p interactions, and diffractive processes. The report includes a detailed study of the trigger strategy, acceptance, reconstruction efficiencies, and expected yields for a particular p p --> p H p measurement with Higgs boson decay in the b-bbar mode. The document also describes the detector acceptance as given by the LHC beam optics between the interaction points and the FP420 location, the machine backgrounds, the new proposed connection cryostat and the moving ("Hamburg") beam-pipe at 420 m, and the radio-frequency impact of the design on the LHC. The last part of the document is devoted to a description of the 3D silicon sensors and associated tracking performances, the design of two fast-timing detectors capable of accurate vertex reconstruction for background rejection at high-luminosities, and the detector alignment and calibration strategy.