Researcher profile

Franz Josef Ahlers

Franz Josef Ahlers contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Ultrastable low-noise current amplifier

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MOhm reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is extremely stable versus time, temperature and current amplitude within the full dynamic range of +/-5 nA. A low noise level of 2.4 fA/sqrt(Hz) helps to keep averaging times low at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Typically, within one day after calibration, the uncertainty contribution from short-term fluctuations of the transresistance is below one part in 10^7. The long-term stability is expected to be better than one part in 10^5 over a year. A high-precision variant is available that shows a substantially improved stability at the expense of a higher noise level of 7.5 fA/sqrt(Hz). The ULCA also allows the traceable generation of small electrical currents or the calibration of high-ohmic resistors.

preprint2011arXiv

Electron Counting Capacitance Standard with an improved five-junction R-pump

The Electron Counting Capacitance Standard currently pursued at PTB aims to close the Quantum Metrological Triangle with a final precision of a few parts in 10^7. This paper reports the considerable progress recently achieved with a new generation of single-electron tunnelling devices. A five-junction R-pump was operated with a relative charge transfer error of five electrons in 10^7, and was used to successfully perform single-electron charging of a cryogenic capacitor. The preliminary result for the single-electron charge quantum has an uncertainty of less than two parts in 10^6 and is consistent with the value of the elementary charge.