Source author record

Felix Bünning

Felix Bünning appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Physics-informed linear regression is competitive with two Machine Learning methods in residential building MPC

Because physics-based building models are difficult to obtain as each building is individual, there is an increasing interest in generating models suitable for building MPC directly from measurement data. Machine learning methods have been widely applied to this problem and validated mostly in simulation; there are, however, few studies on a direct comparison of different models or validation in real buildings to be found in the literature. Methods that are indeed validated in application often lead to computationally complex non-convex optimization problems. Here we compare physics-informed Autoregressive-Moving-Average with Exogenous Inputs (ARMAX) models to Machine Learning models based on Random Forests and Input Convex Neural Networks and the resulting convex MPC schemes in experiments on a practical building application with the goal of minimizing energy consumption while maintaining occupant comfort, and in a numerical case study. We demonstrate that Predictive Control in general leads to savings between 26% and 49% of heating and cooling energy, compared to the building's baseline hysteresis controller. Moreover, we show that all model types lead to satisfactory control performance in terms of constraint satisfaction and energy reduction. However, we also see that the physics-informed ARMAX models have a lower computational burden, and a superior sample efficiency compared to the Machine Learning based models. Moreover, even if abundant training data is available, the ARMAX models have a significantly lower prediction error than the Machine Learning models, which indicates that the encoded physics-based prior of the former cannot independently be found by the latter.

preprint2022arXiv

Robust MPC with data-driven demand forecasting for frequency regulation with heat pumps

With the increased amount of volatile renewable energy sources connected to the electricity grid, and the phase-out of fossil fuel based power plants, there is an increased need for frequency regulation. On the demand side, frequency regulation services can be offered by buildings or districts that are equipped with electric heating or cooling systems, by exploiting their thermal inertia. Existing approaches for tapping into this potential typically rely on dynamic building models, which in practice can be challenging to obtain and maintain. As a result, practical implementations of such systems are scarce. Moreover, actively controlling buildings requires extensive control infrastructure and may cause privacy concerns in district energy systems. Motivated by this, we exploit the thermal inertia of buffer storage for reserves, reducing the building models to demand forecasts here. By combining a control scheme based on Robust Model Predictive Control, with affine policies, and heating demand forecasting based on Artificial Neural Networks with online correction methods, we offer frequency regulation reserves and maintain user comfort with a system comprising a heat pump and buffer storage. While the robust approach ensures occupant comfort, the use of affine policies reduces the effect of disturbance uncertainty on the system state. In a first-of-its-kind experiment with a real district-like building energy system, we demonstrate that the scheme is able to offer reserves in a variety of conditions and track a regulation signal while meeting the heating demand of the connected buildings. 13.4% of the consumed electricity is flexible. In additional numerical studies, we demonstrate that using affine policies significantly decreases the cost function and increases the amount of offered reserves and we investigate the suboptimality in comparison to an omniscient control system.