Source author record

Fanghua Li

Fanghua Li appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Determination of incommensurate modulated structure in Bi2Sr1.6La0.4CuO6+δ by aberration-corrected transmission electron microscopy

Incommensurate modulated structure (IMS) in Bi2Sr1.6La0.4CuO6+δ (BSLCO) has been studied by aberration corrected transmission electron microscopy in combination with high-dimensional (HD) space description. Two images in the negative Cs imaging (NCSI) and passive Cs imaging (PCSI) modes were deconvoluted, respectively. Similar results as to IMS have been obtained from two corresponding projected potential maps (PPMs), but meanwhile the size of dots representing atoms in the NCSI PPM is found to be smaller than that in PCSI one. Considering that size is one of influencing factors of precision, modulation functions for all unoverlapped atoms in BSLCO were determined based on the PPM obtained from the NCSI image in combination with HD space description.

preprint2012arXiv

Study of point spread in aberration-corrected high-resolution transmission electron microscopy

For quantitative electron microscopy high precision position information is necessary so that besides an adequate resolution and sufficiently strong contrast of atoms, small width of peaks which represent atoms in structural images is needed. Size of peak is determined by point spread (PS) of instruments as well as that of atoms when point resolution reach the subangstrom scale and thus PS of instruments is comparable with that of atoms. In this article, relationship between PS with atomic numbers, sample thickness, and spherical aberration coefficients will be studied in both negative Cs imaging (NCSI) and positive Cs imaging (PCSI) modes by means of dynamical image simulation. Through comparing the peak width with different thickness and different values of spherical aberration, NCSI mode is found to be superior to PCSI considering smaller peak width in the structural image.