Researcher profile

Faezeh Marzbanrad

Faezeh Marzbanrad contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Fetal Sleep: A Cross-Species Review of Physiology, Measurement, and Classification

Study Objectives: Fetal sleep is a vital yet underexplored aspect of prenatal neurodevelopment. Its cyclic organization reflects the maturation of central neural circuits, and disturbances in these patterns may offer some of the earliest detectable signs of neurological compromise. This is the first review to integrate more than seven decades of research into a unified, cross-species synthesis of fetal sleep. We examine: (i) Physiology and Ontogeny-comparing human fetuses with animal models; and (ii) Methodological Evolution-transitioning from invasive neurophysiology to non-invasive monitoring and deep learning frameworks. Methods: A structured narrative synthesis was guided by a systematic literature search across four databases (PubMed, Scopus, IEEE Xplore, and Google Scholar). From 2,925 identified records, 171 studies involving fetal sleep-related physiology, sleep-state classification, or signal-based monitoring were included in this review. Results: Across the 171 studies, fetal sleep states become clearly observable as the brain matures. In fetal sheep and baboons, organized cycling between active and quiet sleep emerges at approximately 80%-90% gestation. In humans, this differentiation occurs later, around 95% gestation, with full maturation reached near term. Despite extensive animal research, no unified, clinically validated framework exists for defining fetal sleep states, limiting translation into routine obstetric practice. Conclusions: By integrating evidence across species, methodologies, and clinical contexts, this review provides the scientific foundation for developing objective, multimodal, and non-invasive fetal sleep monitoring technologies-tools that may ultimately support earlier detection of neurological compromise and guide timely prenatal intervention.

preprint2022arXiv

Neonatal Bowel Sound Detection Using Convolutional Neural Network and Laplace Hidden Semi-Markov Model

Abdominal auscultation is a convenient, safe and inexpensive method to assess bowel conditions, which is essential in neonatal care. It helps early detection of neonatal bowel dysfunctions and allows timely intervention. This paper presents a neonatal bowel sound detection method to assist the auscultation. Specifically, a Convolutional Neural Network (CNN) is proposed to classify peristalsis and non-peristalsis sounds. The classification is then optimized using a Laplace Hidden Semi-Markov Model (HSMM). The proposed method is validated on abdominal sounds from 49 newborn infants admitted to our tertiary Neonatal Intensive Care Unit (NICU). The results show that the method can effectively detect bowel sounds with accuracy and area under curve (AUC) score being 89.81% and 83.96% respectively, outperforming 13 baseline methods. Furthermore, the proposed Laplace HSMM refinement strategy is proven capable to enhance other bowel sound detection models. The outcomes of this work have the potential to facilitate future telehealth applications for neonatal care. The source code of our work can be found at: https://bitbucket.org/chirudeakin/neonatal-bowel-sound-classification/

preprint2021arXiv

A New Non-Negative Matrix Co-Factorisation Approach for Noisy Neonatal Chest Sound Separation

Obtaining high-quality heart and lung sounds enables clinicians to accurately assess a newborn's cardio-respiratory health and provide timely care. However, noisy chest sound recordings are common, hindering timely and accurate assessment. A new Non-negative Matrix Co-Factorisation-based approach is proposed to separate noisy chest sound recordings into heart, lung, and noise components to address this problem. This method is achieved through training with 20 high-quality heart and lung sounds, in parallel with separating the sounds of the noisy recording. The method was tested on 68 10-second noisy recordings containing both heart and lung sounds and compared to the current state of the art Non-negative Matrix Factorisation methods. Results show significant improvements in heart and lung sound quality scores respectively, and improved accuracy of 3.6bpm and 1.2bpm in heart and breathing rate estimation respectively, when compared to existing methods.

preprint2021arXiv

Real-Time Multi-Level Neonatal Heart and Lung Sound Quality Assessment for Telehealth Applications

Digital stethoscopes in combination with telehealth allow chest sounds to be easily collected and transmitted for remote monitoring and diagnosis. Chest sounds contain important information about a newborn&#39;s cardio-respiratory health. However, low-quality recordings complicate the remote monitoring and diagnosis. In this study, a new method is proposed to objectively and automatically assess heart and lung signal quality on a 5-level scale in real-time and to assess the effect of signal quality on vital sign estimation. For the evaluation, a total of 207 10s long chest sounds were taken from 119 preterm and full-term babies. Thirty of the recordings from ten subjects were obtained with synchronous vital signs from the Neonatal Intensive Care Unit (NICU) based on electrocardiogram recordings. As reference, seven annotators independently assessed the signal quality. For automatic quality classification, 400 features were extracted from the chest sounds. After feature selection using minimum redundancy and maximum relevancy algorithm, class balancing, and hyper-parameter optimization, a variety of multi-class and ordinal classification and regression algorithms were trained. Then, heart rate and breathing rate were automatically estimated from the chest sounds using adapted pre-existing methods. The results of subject-wise leave-one-out cross-validation show that the best-performing models had a mean squared error (MSE) of 0.49 and 0.61, and balanced accuracy of 57% and 51% for heart and lung qualities, respectively. The best-performing models for real-time analysis (<200ms) had MSE of 0.459 and 0.67, and balanced accuracy of 57% and 46%, respectively. Our experimental results underscore that increasing the signal quality leads to a reduction in vital sign error, with only high-quality recordings having a mean absolute error of less than 5 beats per minute, as required for clinical usage.