Researcher profile

Fabio Muleri

Fabio Muleri contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
13works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2026arXiv

Spectral performance of single-channel plastic and GAGG scintillator bars of the CUbesat Solar Polarimeter (CUSP)

Our Sun is the closest X-ray astrophysical source to Earth. As such, it makes a formidable case study to better understand astrophysical processes. Solar flares are in particular very interesting as they are linked to coronal mass ejections as well as magnetic field reconnection sites in the solar atmosphere. Flares can therefore provide insightful information on the physical processes at play on their production sites, but also on the emission and acceleration of energetic charged particles towards our planet, making it a formidable forecasting tool for space weather. While solar flares are critical to understanding magnetic reconnection and particle acceleration, their hard X-ray polarization -- key to distinguishing between competing theoretical models -- remains poorly constrained by existing observations. To address this, we present the CUbesat Solar Polarimeter (CUSP), a mission under development to perform solar flare polarimetry in the 25-100 keV energy range. CUSP consists of a 6U-XL platform hosting a dual-phase Compton polarimeter. The polarimeter is made of a central assembly of four 4x4 arrays of plastic scintillators, each coupled to multi-anode photomultiplier tubes, surrounded by four strips of eight elongated GAGG scintillator bars coupled to avalanche photodiodes. Both types of sensors from Hamamatsu are respectively read out by the MAROC-3A and SKIROC-2A ASICs from Weeroc. In this manuscript, we present the preliminary spectral performances of single plastic and GAGG channels measured in the laboratory using development boards of the ASICs foreseen for the flight model.

preprint2026arXiv

Unlocking the Future of X-Ray Polarimetry with IXPE: Lessons Learned and Next Steps

This paper discusses issues encountered during the early development of the instrument on the Imaging X-ray Polarimetry Explorer (IXPE), a NASA ASI Small Explorer mission launched on 9 December 2021. IXPE has observed about 100 sources, yielding meaningful polarimetry for most of them. An on-board calibration system mitigated most non-ideal detector behaviors during operations. Data from the on-board polarized and unpolarized X-ray sources are routinely ingested by the flight pipeline to correct the instrument response in a manner transparent to users. Based on its scientific return and payload health, the IXPE mission has been extended through 2028. The lessons learned are informing the design of next-generation X-ray polarimetry missions, as discussed elsewhere in these conferences.

preprint2025arXiv

X-ray linear polarization prediction in Black-Hole binaries and Active Galactic Nuclei and its measurements by IXPE

We present a theoretical framework for the formation of X-ray linear polarization in black hole (BH) source. The X-ray linear polarization originates from up-scatterings of initially soft photons within a hot, optically thick Compton cloud (CC) characterized by a flat geometry. The IXPE observations of several BHs X-ray binaries and of one Seyfert-1 galaxy confirm our theoretical prediction regarding values of the linear polarization P. The goal of this paper is to demonstrate that the main physical parameters of these Galactic and extragalactic sources can be derived without any free parameter using the polarization and X-ray spectral measurements. We estimate the CC optical depth, τ0 for all BHs observed by IXPE, using the plot of P vs μ = cos i, where i is an observer inclination with respect to the normal, and considering the values P for a given source. Using X ray spectral analysis, we obtain the photon index Γ and, analytically determined the CC plasma temperature kBTe. Different BHs (Cyg X 1, 4U 1630 47, LMC X 1, 4U 1957+115, Swift J1727.8 1613, GX 339 4) and the Seyfert 1 NGC 4151 exhibited polarization between 1 and 8 percent level nearly independently of energy. kBTe is in the range between 5 and 90 keV with a smaller value in High/Soft State with respect to Low/Hard State. We find a similarity between the physical parameter and the IXPE findings and we provide evidence suggesting that the CC exhibits a flat geometry.

preprint2023arXiv

Determination of X-ray pulsar geometry with IXPE polarimetry

Using observations of X-ray pulsar Her X-1 by the Imaging X-ray Polarimetry Explorer, we report on a highly significant ($>17σ$) detection of the polarization signal from an accreting neutron star. The observed degree of the linear polarization of $\sim$10\% is found to be far below theoretical expectations for this object, and stays low throughout the spin cycle of the pulsar. Both the polarization degree and the angle exhibit variability with pulse phase, which allowed us to measure the pulsar spin position angle 57(2) deg and the magnetic obliquity 12(4) deg, which is an essential step towards detailed modelling of the intrinsic emission of X-ray pulsars. Combining our results with the optical polarimetric data, we find that the spin axis of the neutron star and the angular momentum of the binary orbit are misaligned by at least $\sim$20 deg, which is a strong argument in support of the models explaining stability of the observed super-orbital variability with the precession of the neutron star.

preprint2022arXiv

A weighted analysis to improve the X-ray polarization sensitivity of IXPE

IXPE is a Small Explorer mission that was launched at the end of 2021 to measure the polarization of X-ray emission from tens of astronomical sources. Its focal plane detectors are based on the Gas Pixel Detector, which measures the polarization by imaging photoelectron tracks in a gas mixture and reconstructing their initial directions. The quality of the single track, and then the capability of correctly determining the original direction of the photoelectron, depends on many factors, e.g., whether the photoelectron is emitted at low or high inclination with respect to the collection plane or the occurrence of a large Coulomb scattering close to the generation point. The reconstruction algorithm used by IXPE to obtain the photoelectron emission direction, also calculates several properties of the shape of the tracks which characterize the process. In this paper we compare several such properties and identify the best one to weight each track on the basis of the reconstruction accuracy. We demonstrate that significant improvement in sensitivity can be achieved with this approach and for this reason it will be the baseline for IXPE data analysis.

preprint2022arXiv

Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation

IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

preprint2022arXiv

CUSP: a two cubesats constellation for Space Weather and solar flares X-ray polarimetry

The CUbesat Solar Polarimeter (CUSP) project aims to develop a constellation of two CubeSats orbiting the Earth to measure the linear polarisation of solar flares in the hard X-ray band by means of a Compton scattering polarimeter on board of each satellite. CUSP will allow to study the magnetic reconnection and particle acceleration in the flaring magnetic structures. CUSP is a project approved for a Phase A study by the Italian Space Agency in the framework of the Alcor program aimed to develop CubeSat technologies and missions.

preprint2022arXiv

Limits on X-ray Polarization at the Core of Centaurus A as Observed with the Imaging X-ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the $2-8 \thinspace \mathrm{keV}$ band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at $99 \%$ percent confidence (MDP$_{99}$) of $6.5 \%$ using a weighted, spectral model-independent calculation in the $2-8 \thinspace \mathrm{keV}$ band. The polarization angle $ψ$ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy ($0.3-400 \thinspace \mathrm{keV}$) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption ($N_H \sim 10^{23} \thinspace \mathrm{cm}^{-2}$) and a Fe K$α$ emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below $2 \thinspace \mathrm{keV}$. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe K$α$ emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

preprint2022arXiv

Simultaneous space and phase resolved X-ray polarimetry of the Crab Pulsar and Nebula

The Crab pulsar and its nebula are among the most studied astrophysical systems, and constitute one of the most promising environments where high energy processes and particle acceleration can be investigated. They are the only objects for which previous X-ray polarisation has been reported. We present here the first Imaging X-ray Polarimetry Explorer (IXPE) observation of the Crab pulsar and nebula. The total pulsar pulsed emission in the [2-8] keV energy range is unpolarised. Significant polarisation up to 15% is detected only in the core of the main peak. The nebula has a total space integrated polarised degree of 20% and polarisation angle of 145deg. The polarised maps show a large variation in the local polarisation, and regions with polarised degree up to 45-50%. The polarisation pattern suggests a predominantly toroidal magnetic field.

preprint2021arXiv

A significant detection of X-ray Polarization in Sco X-1 with PolarLight and constraints on the corona geometry

We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$σ$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$σ$ detection during high fluxes, in which case we obtain a polarization fraction of $0.043 \pm 0.008$ and a polarization angle of $52.6^\circ \pm 5.4^\circ$. This confirms a previous marginal detection with OSO-8 in the 1970s, and marks Sco X-1 the second astrophysical source with a significant polarization measurement in the keV band. The measured polarization angle is in line with the jet orientation of the source on the sky plane ($54^\circ$), which is supposedly the symmetric axis of the system. Combining previous spectral analysis, our measurements suggest that an optically thin corona is located in the transition layer under the highest accretion rates, and disfavor the extended accretion disk corona model.

preprint2021arXiv

A Study of background for IXPE

Focal plane X-ray polarimetry is intended for relatively bright sources with a negligible impact of background. However this might not be always possible for IXPE (Imaging X-ray Polarimetry Explorer) when observing faint extended sources like supernova remnants. We present for the first time the expected background of IXPE by Monte Carlo simulation and its impact on real observations of point and extended X-ray sources. The simulation of background has been performed by Monte Carlo based on GEANT4 framework. The spacecraft and the detector units have been modeled, and the expected background components in IXPE orbital environment have been evaluated. We studied different background rejection techniques based on the analysis of the tracks collected by the Gas Pixel Detectors on board IXPE. The estimated background is about 2.9 times larger than the requirement, yet it is still negligible when observing point like sources. Albeit small, the impact on supernova remnants indicates the need for a background subtraction for the observation of the extended sources.

preprint2021arXiv

An algorithm to calibrate and correct the response to unpolarized radiation of the X-ray polarimeter on board IXPE

The Gas Pixel Detector is an X-ray polarimeter to fly on-board IXPE and other missions. To correctly measure the source polarization, the response of IXPE's GPDs to unpolarized radiation has to be calibrated and corrected. In this paper we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and non-monochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

preprint2020arXiv

In-orbit Operation and Performance of the CubeSat Soft X-ray Polarimeter PolarLight

PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we discuss how one can run a low-cost, shared CubeSat for space astronomy, and how CubeSats can play a role in modern space astronomy for technical demonstration, science observations, and student training.