Source author record

Fabien Grisé

Fabien Grisé appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

High Efficiency Echelle Gratings for the Far Ultraviolet

Modern grating manufacturing techniques suffer from inherent issues that limit their peak efficiencies. The anisotropic etching of silicon facilitates the creation of custom gratings that have sharp and atomically smooth facets, directly addressing these issues. We describe work to fabricate and characterize etched silicon echelles optimized for the far ultraviolet (FUV; 90 - 180 nm) bandpass. We fabricate two echelles that have similar parameters to the mechanically ruled grating flown on the CHESS sounding rocket. We demonstrate a 42% increase in peak order efficiency and an 83% decrease in interorder scatter using these gratings. We also present analysis on where the remaining efficiency resides. These demonstrated FUV echelle improvements benefit the faint source sensitivity and high-resolution performance of future UV observatories.

preprint2021arXiv

A Comprehensive Line-Spread Function Error Budget for the Off-Plane Grating Rocket Experiment

The Off-plane Grating Rocket Experiment (OGRE) is a soft X-ray grating spectrometer to be flown on a suborbital rocket. The payload is designed to obtain the highest-resolution soft X-ray spectrum of Capella to date with a resolution goal of $R(λ/Δλ)>2000$ at select wavelengths in its 10--55 Angstrom bandpass of interest. The optical design of the spectrometer realizes a theoretical maximum resolution of $R\approx5000$, but this performance does not consider the finite performance of the individual spectrometer components, misalignments between components, and in-flight pointing errors. These errors all degrade the performance of the spectrometer from its theoretical maximum. A comprehensive line-spread function (LSF) error budget has been constructed for the OGRE spectrometer to identify contributions to the LSF, to determine how each of these affects the LSF, and to inform performance requirements and alignment tolerances for the spectrometer. In this document, the comprehensive LSF error budget for the OGRE spectrometer is presented, the resulting errors are validated via raytrace simulations, and the implications of these results are discussed.

preprint2015arXiv

A Luminous X-ray Flare From The Nucleus of The Dormant Bulgeless Spiral Galaxy NGC 247

NGC 247 is a nearby late-type bulgeless spiral galaxy that contains an inactive nucleus. We report a serendipitous discovery of an X-ray flare from the galaxy center with a luminosity up to 2*10^39 erg/s in the 0.3-10 keV band with XMM-Newton. A Chandra observation confirms that the new X-ray source is spatially coincident with the galaxy nucleus. The XMM-Newton data revealed a hard power-law spectrum with a spectral break near 3-4 keV, no pulsations on timescales longer than 150 ms, and a flat power spectrum consistent with Poisson noise from 1 mHz to nearly 10 Hz. Follow-up observations with Swift detected a second flux peak followed by a luminosity drop by factor of almost 20. The spectral and temporal behaviors of the nuclear source are well consistent with the scenario that the flare was due to an outburst of a low-mass X-ray binary that contains a stellar-mass black hole emitting near its Eddington limit at the peak. However, it cannot be ruled out that the sudden brightening in the nucleus was due to accretion onto a possible low-mass nuclear black hole, fed by a tidally disrupted star or a gas cloud; the MAXI observations limit the peak luminosity of the flare to less than ~10^43 erg/s, suggesting that it is either a low mass black hole or an inefficient tidal disruption event (TDE).

preprint2013arXiv

A long-term X-ray monitoring of the ultraluminous X-ray source NGC 5408 X-1 with Swift reveals the presence of dips but no orbital period

NGC 5408 X-1 is a well-studied ultraluminous X-ray source (ULX) that has been seen to emit in X-rays persistently above the Eddington limit of a stellar-mass black hole for years. In this paper we report on the most extensive X-ray monitoring of a ULX, using more than four years of observations from the Swift satellite. We find that the 115 day periodicity reported by Strohmayer (2009) disappeared after only a few cycles, confirming the suspicion of Foster et al. (2010) that the periodicity is most likely super-orbital and not the orbital period of the system. We also report on a clear dipping behaviour of the source that may be related to a (super)-orbital phenomenon. All these features are reminiscent of Galactic X-ray binaries and strengthen their link with ULXs. Deeper observations of a dip could help resolve the ambiguity about the interpretation of the spectral components of ULXs.

preprint2012arXiv

Chandra and HST Observations of the Supersoft ULX in NGC 247: Candidate for Standard Disk Emission

We report on multiwavelength observations of the supersoft ultraluminous X-ray source (ULX) in NGC 247 made with the Chandra X-ray Observatory and Hubble Space Telescope (HST). We aligned the X-ray and optical images using three objects present on both and identified a unique, point-like optical counterpart to the ULX. The X-ray to optical spectrum is well fitted with an irradiated disk model if the extinction measured for Cepheids in NGC 247 is used. Assuming only Galactic extinction, then the spectrum can be modeled as a standard thin accretion disk. Either result leads to the conclusion that a disk interpretation of the X-ray spectrum is valid, thus the source may be in the X-ray thermal state and contain an intermediate mass black hole of at least 600 solar masses. In contrast to other supersoft ULXs which are transient and exhibit a luminosity temperature relation inconsistent with a disk interpretation of the X-ray emission, the NGC 247 ULX has a relatively steady flux and all available X-ray data are consistent with emission from a disk in the thermal state.

preprint2012arXiv

The Nature of the UV/optical Emission of the Ultraluminous X-Ray Source in Holmberg II

We report on UV and X-ray spectroscopy and broad-band optical observations of the ultraluminous X-ray source in Holmberg II. Fitting various stellar spectral models to the combined, non-simultaneous data set, we find that normal metallicity stellar spectra are ruled out by the data, while low metallicity, Z = 0.1 Z_{\odot}, late O-star spectra provide marginally acceptable fits, if we allow for the fact that X-ray ionization from the compact object may reduce or eliminate UV absorption/emission lines from the stellar wind. By contrast, an irradiated disk model fits both UV and optical data with chi^2/dof=175.9/178, and matches the nebular extinction with a reddening of E(B-V)=0.05^{+0.05}_{-0.04}. These results suggest that the UV/optical flux of Holmberg II X-1 may be dominated by X-ray irradiated disk emission.

preprint2011arXiv

Optical emission of the ultraluminous X-ray source NGC 5408 X-1: donor star or irradiated accretion disk?

We obtained 3 epochs of simultaneous Hubble Space Telescope (HST)/Wide Field Camera 3 and Chandra observations of the ultraluminous X-ray source NGC 5408 X-1. The counterpart of the X-ray source is seen in all HST filters, from the UV through the NIR, and for the first time, we resolve the optical nebula around the ULX. We identified a small OB association near the ULX that may be the birthplace of the system. The stellar association is young, ~ 5 Myr, contains massive stars up to 40 solar masses, and is thus similar to associations seen near other ULXs, albeit younger. The UV/Optical/NIR spectral energy distribution (SED) of the ULX counterpart is consistent with that of a B0I supergiant star. We are also able to fit the whole SED from the X-rays to the NIR with an irradiated disk model. The three epochs of data show only marginal variability and thus, we cannot firmly conclude on the nature of the optical emission.

preprint2011arXiv

Optical Properties of the Ultraluminous X-ray Source Holmberg IX X-1 and its Stellar Environment

Holmberg IX X-1 is an archetypal ultraluminous X-ray source (ULX). Here we study the properties of the optical counterpart and of its stellar environment using optical data from SUBARU/Faint Object Camera and Spectrograph,GEMINI/GMOS-N and Hubble Space Telescope (HST)/Advanced Camera for Surveys, as well as simultaneous Chandra X-ray data. The V ~ 22.6 spectroscopically identified optical counterpart is part of a loose cluster with an age <~ 20 Myr. Consequently, the mass upper limit on individual stars in the association is about 20 M_sun. The counterpart is more luminous than the other stars of the association, suggesting a non-negligible optical contribution from the accretion disk. An observed UV excess also points to non-stellar light similar to X-ray active low-mass X-ray binaries. A broad HeII4686 emission line identified in the optical spectrum of the ULX further suggests optical light from X-ray reprocessing in the accretion disk. Using stellar evolutionary tracks, we have constrained the mass of the counterpart to be >~ 10 M_sun, even if the accretion disk contributes significantly to the optical luminosity. Comparison of the photometric properties of the counterpart with binary models show that the donor may be more massive, >~ 25 M_sun, with the ULX system likely undergoing case AB mass transfer. Finally, the counterpart exhibits photometric variability of 0.14 mag between two HST observations separated by 50 days which could be due to ellipsoidal variations and/or disk reprocessing of variable X-ray emission.

preprint2010arXiv

X-ray spectral state is not correlated with luminosity in Holmberg II X-1

The ultraluminous X-ray source (ULX) Holmberg II X-1 has been observed over 4 months in 2009/2010 by the Swift observatory. The source luminosity varied by a factor of up to 14, reaching a maximum 0.3-10 keV luminosity of ~3.0E40 erg/s. The spectral properties do not vary much over these 4 months, with only a slight monotonic increase of the hardness ratio with the count rate. This means that the erratic flaring activity of the source is not associated with spectral changes, as seen in other ULXs. Conversely, comparison with data obtained by Swift in 2006 shows a completely different picture: while at a luminosity also seen in the 2009/2010 data, the source appears with a hard spectrum. Thus, it appears that, as in Galactic black hole binaries, spectral states in this ULX are not determined only by the X-ray luminosity.