Source author record

F. Proebst

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
8topics
4close collaborators

Published work

4 publications

preprint2020arXiv

New limits on the resonant absorption of solar axions obtained with a 169^{169}Tm-containing cryogenic detector

A search for resonant absorption of solar axions by 169^{169}Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on Tm3_3Al5_5O12_{12} crystal was used that allowed for significant improvement of sensitivity in comparison with previous 169^{169}Tm based experiments. The measurements performed with 8.188.18 g crystal during 6.66.6 days exposure yielded the following limits on axion couplings: ∣gAγ(gAN0+gAN3)≤1.44×10−14|g_{Aγ} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14} GeV−1^{-1} and ∣gAe(gAN0+gAN3)≤2.81×10−16|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}.

preprint2007arXiv

Brittle fracture down to femto-Joules - and below

We analyze large sets of energy-release data created by stress-induced brittle fracture in a pure sapphire crystal at close to zero temperature where stochastic fluctuations are minimal. The waiting-time distribution follows that observed for fracture in rock and for earthquakes. Despite strong time correlations of the events and the presence of large-event precursors, simple prediction algorithms only succeed in a very weak probabilistic sense. We also discuss prospects for further cryogenic experiments reaching close to single-bond sensitivity and able to investigate the existence of a transition-stress regime.

preprint2004arXiv

The CRESST Dark Matter Search

We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils. The observed count rate in the neutron band is compatible with the rate expected from neutron background. CRESST is presently being upgraded with a 66 channel SQUID readout system, a neutron shield and a muon veto system. This results in a significant improvement in sensitivity.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.