Researcher profile

F. Hoyo

F. Hoyo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2019arXiv

CAFE2: an upgrade to the CAFE high-resolution spectrograph. Commissioning results and new public pipeline

The Calar Alto Fiber-fed Échelle spectrograph (CAFE) is a high-resolution spectrographs with high-precision radial velocity capabilities mounted in the 2.2m telescope of Calar Alto Observatory. It suffered from strong degradation after 4 years of operations and it has now been upgraded. The upgrades of the instrument (now named CAFE$_2$) aimed at improving the throughput and stability thanks to the inclusion of a new grating, an active temperature control in the isolated coudé room, and a new scrambling system among other minor changes. In this paper, we present the results of the re-commissioning of the instrument and a new pipeline (CAFExtractor) that provides the user with fully reduced data including radial velocity measurements of FGK dwarf stars. We have monitored the upgraded instrument for several months to characterize its main properties and test the new pipeline. It uses part of the CERES code, improves the wavelength calibration and radial velocity extraction (using the HARPS masks adapted), applies nightly drift corrections. The finally reduced spectra are presented in FITS files. The commissioning results show a clear improvement in the instrument performance with respect to the degraded status before the intervention. The room temperature is now stabilized down to 5 mK during one night and below 50 mK over two months. CAFE$_2$ now provides 3 m/s precision on the reference ThAr frames and the on-sky tests provide a radial velocity precision of 8 m/s during one night (for S/N>50). The throughput of the instrument is now back to nominal values with an efficiency of around 15% at 550 nm. The limiting magnitude of the instrument for a 1h exposure and S/N=20 is V=15. With all these properties, CAFE$_2$ enters into the small family of high-resolution spectrographs mounted on 2-4 meter-class telescopes capable of reaching radial velocity precisions below 10 m/s.