Source author record

Eugene Ivanov

Eugene Ivanov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

Low Noise Microwaves for Testing Fundamental Physics

We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission coefficient of the cryogenic resonator we computed its noise suppression function. This was done via Monte-Carlo simulations some details of which are discussed in this Letter. Next, we measured technical fluctuations of a signal incident on the cryogenic resonator. Having processed these data with the previously computed noise filtering "template" we inferred noise spectra of the transmitted signal. We found that spectral densities of both phase and amplitude fluctuations of the transmitted signal were close to the thermal noise limit of -180 dB/Hz at Fourier frequencies F $\ge$ 10 kHz. Such thermal noise limited microwaves allow more precise tests of special relativity and could be useful at some stages of quantum signal processing.

preprint2015arXiv

Precision Measurement of a low-loss Cylindrical Dumbbell-Shaped Sapphire Mechanical Oscillator using Radiation Pressure

We present first results from a number of experiments conducted on a 0.53 kg cylindrical dumbbell-shaped sapphire crystal. This is the first reported optomechanical experiment of this nature utilising a novel modification to the typical cylindrical architecture. Mechanical motion of the crystal structure alters the dimensions of the crystal, and the induced strain changes the permittivity. These two effects result in parametric frequency modulation of resonant microwave whispering gallery modes that are simultaneously excited within the crystal. A novel low-noise microwave readout system is implemented allowing extremely low noise measurements of this frequency modulation near our modes of interest, having a phase noise floor of -165 dBc/Hz at 100 kHz. Fine-tuning of the crystal's suspension has allowed for the optimisation of mechanical quality factors in preparation for cryogenic experiments, with a value of Q=8 x 10^7 achieved at 127 kHz. This results in a Q x f product of 10^13, equivalent to the best measured values in a macroscopic sapphire mechanical system. Results are presented that demonstrate the excitation of mechanical modes via radiation pressure force, allowing an experimental method of determining the transducer's displacement sensitivity df/dx, and calibrating the system. Finally, we demonstrate parametric back-action phenomenon within the system. These are all important steps towards the overall goal of the experiment; to cool a macroscopic device to the quantum ground state at millikelvin temperatures.

preprint2014arXiv

Sub-Doppler cooling of ytterbium with the $^{1}S_{0}$-$^{1}P_{1}$ transition including $^{171}$Yb (I=1/2)

We report on the sub-Doppler laser cooling of neutral $^{171}$Yb and $^{173}$Yb in a magneto-optical trap using the $^{1}S_{0}$-$^{1}P_{1}$ transition at 398.9nm. We use two independent means to estimate the temperature of the atomic cloud for several of the Yb isotopes. The two methods of MOT-cloud-imaging and release-and-recapture show consistency with one another. Temperatures below 400$μ$K and 200$μ$K are recorded for $^{171}$Yb and $^{173}$Yb, respectively, while ~1mK is measured for both $^{172}$Yb and $^{174}$Yb. By comparison, the associated 1D Doppler cooling temperature limit is 694$μ$K. The sub-Doppler cooling of the I=1/2 $^{171}$Yb isotope in a $σ^{+}-σ^{-}$ light-field trap adds further evidence that the Sisyphus cooling mechanism is occurring in such 3D magneto-optical traps.

preprint2013arXiv

Metallic spintronic nanofilm as a hydrogen sensor

We investigate the response of palladium-cobalt bi-layer thin films to hydrogen charging at atmospheric pressure for spintronic applications. We find that hydrogen absorption by the palladium layer results in the narrowing and shifting of the ferromagnetic resonance line for the material. We explain the observed phenomena as originating from reduction in spin pumping effect and from variation in the magnetic anisotropy of the cobalt film through an interface effect. The shift of the resonance frequency or field is the easiest to detect. We utilize it to demonstrate functionality of the bi-layer films as a hydrogen sensor.

preprint2012arXiv

A transposed frequency technique for phase noise and frequency stability measurements

The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency technique, which extends the frequency range of digital noise measurements to the microwave domain and beyond. We discuss two basic variations of the proposed noise measurement technique, one of which enables characterization of phase fluctuations added to the passing signal by the particular microwave component, for example by an amplifier, while another one is intended for measurements of phase fluctuations of the incoming signal itself.

preprint2009arXiv

Method of Power Recycling in Co-Axial Mach Zender Interferometers for Low Noise Measurements

We present the first experimental study of a new type of power recycling microwave interferometer designed for low noise measurements. This system enhances sensitivity to phase fluctuations in a Device Under Test, independent of input power levels. The single sideband thermal white phase noise floor of the system has been lowered by 8 dB (reaching -185 dBc/Hz at 1 kHz offset frequency) at relatively low power levels (13 dBm).