Researcher profile

Eric Delagnes

Eric Delagnes contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

IDeF-X HD: a CMOS ASIC for the readout of Cd(Zn)Te Detectors for space-borne applications

IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after shaping with 10.7 micro seconds peak time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2 keV FWHM at 667 keV (137-Cs) on a mono-pixel configuration. Meanwhile, we also measured 562 eV and 666 eV FWHM at 14 keV and 60 keV respectively (241-Am) with a 256 small pixel array and a low detection threshold of 1.2 keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the Linear Energy Transfer threshold above 110 MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high-energy resolution. The chip is space qualified and flies on board the Solar Orbiter ESA mission launched in 2020.

preprint2020arXiv

A NECTAr-based upgrade for the Cherenkov cameras of the H.E.S.S. 12-meter telescopes

The High Energy Stereoscopic System (H.E.S.S.) is one of the three arrays of imaging atmospheric Cherenkov telescopes (IACTs) currently in operation. It is composed of four 12-meter telescopes and a 28-meter one, and is sensitive to gamma rays in the energy range ~30 GeV - 100 TeV. The cameras of the 12-m telescopes recently underwent a substantial upgrade, with the goal of improving their performance and robustness. The upgrade involved replacing all camera components except for the photomultiplier tubes (PMTs). This meant developing new hardware for the trigger, readout, power, cooling and mechanical systems, and new software for camera control and data acquisition. Several novel technologies were employed in the cameras: the readout is built around the new NECTAr digitizer chip, developed for the next generation of IACTs; the camera electronics is fully controlled and read out via Ethernet using a combination of FPGA and embedded ARM computers; the software uses modern libraries such as Apache Thrift, ZMQ and Protocol buffers. This work describes in detail the design and the performance of the upgraded cameras.