Researcher profile

Erez Etzion

Erez Etzion contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

preprint2022arXiv

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

preprint2020arXiv

An Update to the Letter of Intent for MATHUSLA: Search for Long-Lived Particles at the HL-LHC

We report on recent progress in the design of the proposed MATHUSLA Long Lived Particle (LLP) detector for the HL-LHC, updating the information in the original Letter of Intent (LoI), see CDS:LHCC-I-031, arXiv:1811.00927. A suitable site has been identified at LHC Point 5 that is closer to the CMS Interaction Point (IP) than assumed in the LoI. The decay volume has been increased from 20 m to 25 m in height. Engineering studies have been made in order to locate much of the decay volume below ground, bringing the detector even closer to the IP. With these changes, a 100 m x 100 m detector has the same physics reach for large c$τ$ as the 200 m x 200 m detector described in the LoI and other studies. The performance for small c$τ$ is improved because of the proximity to the IP. Detector technology has also evolved while retaining the strip-like sensor geometry in Resistive Plate Chambers (RPC) described in the LoI. The present design uses extruded scintillator bars read out using wavelength shifting fibers and silicon photomultipliers (SiPM). Operations will be simpler and more robust with much lower operating voltages and without the use of greenhouse gases. Manufacturing is straightforward and should result in cost savings. Understanding of backgrounds has also significantly advanced, thanks to new simulation studies and measurements taken at the MATHUSLA test stand operating above ATLAS in 2018. We discuss next steps for the MATHUSLA collaboration, and identify areas where new members can make particularly important contributions.

preprint2020arXiv

Liquid Scintillators for Large Area Tracking System

We report on studies of non-toxic scintillating liquid useful for large surface detectors. Arrays of liquid scintillators offer a rather simple tool for detecting charged particles traversing a surface and tracking their path through a defined volume. Insertion of wavelength shifting fibres along the liquid scintillating containers significantly improves the light collection at the two ends of the scintillators. We have demonstrated that we can achieve timing resolution of O(1 ns) allowing good spatial resolution. Liquid scintillators with fibres read by Photo-multipliers or SiPMs provide an inexpensive alternative technology which suits well the requirement of the MATHUSLA experiment tracking system.