Source author record

Emmanuel Bossy

Emmanuel Bossy appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2021arXiv

Roadmap on Wavefront Shaping and deep imaging in complex media

The last decade has seen the development of a wide set of tools, such as wavefront shaping, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tissues. This roadmap highlights several key aspects of this fast developing field, and some of the challenges and opportunities ahead.

preprint2020arXiv

Single-shot hybrid photoacoustic-fluorescent microendoscopy through a multi-mode fiber with wavefront shaping

We present a minimally-invasive endoscope based on a multimode fiber that combines photoacoustic and fluorescence sensing. From the measurement of a transmission matrix during a prior calibration step, a focused spot is produced and raster-scanned over a sample at the distal tip of the fiber by use of a fast spatial light modulator. An ultra-sensitive fiber-optic ultrasound sensor for photoacoustic detection placed next to the fiber is combined with a photodetector to obtain both fluorescence and photoacoustic images with a distal imaging tip no larger than 250um. The high signal-to-noise ratio provided by wavefront shaping based focusing and the ultra-sensitive ultrasound sensor enables imaging with a single laser shot per pixel, demonstrating fast two-dimensional hybrid imaging of red blood cells and fluorescent beads.

preprint2019arXiv

Theoretical and experimental study of photoacoustic excitation of silica-coated gold nanospheres in water

Silica-coated gold nanoparticles are commonly employed in biomedical photoacoustic (PA) imaging applications. We investigate theoretically and experimentally the PA signal generation by silica-coated gold nanospheres in water. Our theoretical model considers thermoelastic expansion in the long-pulse illumination regime, and the PA signals are determined based on a semi-analytical solution to the thermal diffusion equations and a finite-difference in time domain (FDTD) solution to the thermoelastic equations. Both the influence of interfacial thermal (Kapitza) resistance at the gold-water boundary and the influence of the silica coating on PA signal generation were investigated. Our results indicate that for the nanosecond pulses commonly employed in PA imaging, Kapitza resistance has a negligible effect on photoacoustic signal generation. Moreover, our model shows that the presence of a silica coating causes a reduction in the PA signal amplitude, with the level of signal reduction increasing with thicker silica coating. Our theoretical predictions are qualitatively consistent with our experimental results, where suspensions of in-house-synthesized and commercially available silica-coated gold nanosphere suspensions were excited with nanosecond-pulsed laser illumination at 532 nm. The PA signal amplitudes from silica-coated nanospheres were lower than the signal amplitudes for uncoated gold nanospheres of the same core gold diameter. The amount of reduction of the experimentally PA signal amplitude due to the silica coating was found to increase with thicker silica coating, in agreement with our theoretical predictions.

preprint2015arXiv

Photoacoustic generation by a gold nanosphere: From linear to nonlinear thermoelastics in the long-pulse illumination regime

We investigate theoretically the photoacoustic generation by a gold nanosphere in water in the thermoelastic regime. Specifically, we consider the long-pulse illumination regime, in which the time for electron-phonon thermalisation can be neglected and photoacoustic wave generation arises solely from the thermo-elastic stress caused by the temperature increase of the nanosphere or its liquid environment. Photoacoustic signals are predicted computed based on the successive resolution of a thermal diffusion problem and a thermoelastic problem, taking into account the finite size of the gold nanosphere and the temperature-dependence of the thermal expansion coefficient of water. For sufficiently high illumination fluences, this temperature dependence yields a nonlinear relationship between the photoacoustic amplitude and the fluence. For nanosecond pulses in the linear regime, we show that more than 90 % of the emitted photoacoustic energy is generated in water, and the thickness of the generating layer around the particle scales close to the square root of the pulse duration. Our results demonstrate that the point-absorber model introduced by Calasso et al.[17] significantly overestimates the amplitude of photoacoustic waves in the nonlinear regime. We therefore provide quantitative estimates of a critical energy, defined as the absorbed energy required such that the nonlinear contribution is equal to that of the linear contribution. Our results suggest that the critical energy scales as the volume of water over which heat diffuses during the illumination pulse. Moreover, thermal nonlinearity is shown to be expected only for sufficiently high ultrasound frequency. Finally, we show that the relationship between the photoacoustic amplitude and the equilibrium temperature at sufficiently high fluence reflects the thermal diffusion at the nanoscale around the gold nanosphere.

preprint2015arXiv

Single-side access, isotropic resolution and multispectral 3D photoacoustic imaging with rotate-translate scanning of ultrasonic detector array

Photoacoustic imaging can achieve high-resolution three-dimensional visualization of optical absorbers at penetration depths ~ 1 cm in biological tissues by detecting optically-induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized and high-frequency detection, but usually comes with an image quality impaired by the directionality of the detectors. Indeed, a simple translation of the array perpendicularly to its median imaging plane is often used, but results both in a poor resolution in the translation direction and in strong limited view artifacts. To improve the spatial resolution and the visibility of complex structures while keeping a planar detection geometry, we introduce, in this paper, a novel rotate-translate scanning scheme, and investigate the performance of a scanner implemented at 15 MHz center frequency. The developed system achieved a quasi-isotropic uniform 3D resolution of ~170 um over a cubic volume of side length 8.5 mm, i.e. an improvement in the resolution in the translation direction by almost one order of magnitude. Dual wavelength imaging was also demonstrated with ultrafast wavelength shifting. The validity of our approach was shown in vitro. We discuss the ability to enable in vivo imaging for preclinical and clinical studies.

preprint2015arXiv

Super-resolution photoacoustic fluctuation imaging with multiple speckle illumination

In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of the photoacoustic images combined with image deconvolution enables resolving optically absorbing structures beyond the acoustic diffraction limit. A resolution increase of almost a factor 2 is demonstrated experimentally. Our method introduces a new framework that could potentially lead to deep tissue photoacoustic imaging with sub-acoustic resolution.

preprint2013arXiv

Improving Photoacoustic-guided Focusing in Scattering Media by Spectrally Filtered Detection

We experimentally and numerically study the potential of photoacoustic-guiding for light focusing through scattering samples via wavefront-shaping and iterative optimization. We experimentally demonstrate that the focusing efficiency on an extended absorber can be improved by iterative optimization of the high frequency components of the broadband photoacoustic signal detected with a spherically focused transducer. We demonstrate more than 8-fold increase in the photoacoustic signal generated by a 30 microns wire using a narrow frequency band around 60MHz. We numerically confirm that such optimization leads to a smaller optical focus than using the low frequency content of the photoacoustic feedback.

preprint2013arXiv

Improving visibility in photoacoustic imaging using dynamic speckle illumination

In high-frequency photoacoustic imaging with uniform illumination, homogeneous photo-absorbing structures may be invisible because of their large size or limited-view issues. Here we show that, by exploiting dynamic speckle illumination, it is possible to reveal features which are normally invisible with a photoacoustic system comprised of a 20MHz linear ultrasound array. We demonstrate imaging of a 5 mm diameter absorbing cylinder and a 30 micrometer black thread arranged in a complex shape. The hidden structures are directly retrieved from photoacoustic images recorded for different random speckle illuminations of the phantoms by assessing the variation in the value of each pixel over the illumination patterns.

preprint2013arXiv

Optical-resolution photoacoustic microscopy by use of a multimode fiber

We demonstrate Optical-Resolution Photoacoustic Microscopy (OR-PAM), where the optical field is focused and scanned using Digital Phase Conjugation (DPC) through a multimode fiber. The focus is scanned across the field of view using digital means, and the acoustic signal induced is collected by a transducer. Optical-resolution photoacoustic images of a knot made by two absorptive wires are obtained and we report on resolution smaller than 1.5μm across a 201μm by 201μm field of view. The use of a multimode optical fiber for the optical excitation part can pave the way for miniature endoscopes that can provide optical-resolution photoacoustic images at large optical depth.

preprint2013arXiv

Radiative transfer and diffusion limits for wave field correlations in locally shifted random media

The aim of this paper is to develop a mathematical framework for opto-elastography. In opto-elastography, a mechanical perturbation of the medium produces a decorrelation of optical speckle patterns due to the displacements of optical scatterers. To model this, we consider two optically random media, with the second medium obtained by shifting the first medium in some local region. We derive the radiative transfer equation for the cross-correlation of the wave fields in the media. Then we derive its diffusion approximation. In both the radiative transfer and the diffusion regimes, we relate the correlation of speckle patterns to the solutions of the radiative transfer and the diffusion equations. We present numerical simulations based on our model which are in agreement with recent experimental measurements.

preprint2012arXiv

Acousto-optical coherence tomography with a digital holographic detection scheme

Acousto-optical coherence tomography (AOCT) consists in using random phase jumps on ultrasound and light to achieve a millimeter resolution when imaging thick scattering media. We combined this technique with heterodyne off-axis digital holography. Two-dimensional images of absorbing objects embedded in scattering phantoms are obtained with a good signal-to-noise ratio. We study the impact of the phase modulation characteristics on the amplitude of the acousto-optic signal and on the contrast and apparent size of the absorbing inclusion.