Researcher profile

Edward B. Fomalont

Edward B. Fomalont contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only 0.7deg away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14x11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

preprint2020arXiv

ALMA High-frequency Long Baseline Campaign in 2017: Band-to-band Phase Referencing in Submillimeter Waves

In 2017, an Atacama Large Millimeter/submillimeter Array (ALMA) high-frequency long baseline campaign was organized to test image capabilities with baselines up to 16 km at submillimeter (submm) wavelengths. We investigated image qualities using ALMA receiver Bands 7, 8, 9, and 10 (285-875 GHz) by adopting band-to-band (B2B) phase referencing in which a phase calibrator is tracked at a lower frequency. For B2B phase referencing, it is expected that a closer phase calibrator to a target can be used, comparing to standard in-band phase referencing. In the first step, it is ensured that an instrumental phase offset difference between low- and high-frequency Bands can be removed using a differential gain calibration in which a phase calibrator is certainly detected while frequency switching. In the next step, comparative experiments are arranged to investigate the image quality between B2B and in-band phase referencing with phase calibrators at various separation angles. In the final step, we conducted long baseline imaging tests for a quasar at 289 GHz in Band 7 and 405 GHz in Band 8 and complex structure sources of HL Tau and VY CMa at ~670 GHz in Band 9. The B2B phase referencing was successfully applied, allowing us to achieve an angular resolution of 14x11 and 10x8 mas for HL Tau and VY CMa, respectively. There is a high probability of finding a low-frequency calibrator within 5.4 deg in B2B phase referencing, bright enough to use an 8 s scan length combined with a 7.5 GHz bandwidth.

preprint2020arXiv

ALMA High-frequency Long-baseline Campaign in 2017: A Comparison of the Band-to-band and In-band Phase Calibration Techniques and Phase-calibrator Separation Angles

The Atacama Large millimeter/submillimeter Array (ALMA) obtains spatial resolutions of 15 to 5 milli-arcsecond (mas) at 275-950GHz (0.87-0.32mm) with 16km baselines. Calibration at higher-frequencies is challenging as ALMA sensitivity and quasar density decrease. The Band-to-Band (B2B) technique observes a detectable quasar at lower frequency that is closer to the target, compared to one at the target high-frequency. Calibration involves a nearly constant instrumental phase offset between the frequencies and the conversion of the temporal phases to the target frequency. The instrumental offsets are solved with a differential-gain-calibration (DGC) sequence, consisting of alternating low and high frequency scans of strong quasar. Here we compare B2B and in-band phase referencing for high-frequencies ($>$289GHz) using 2-15km baselines and calibrator separation angles between $\sim$0.68 and $\sim$11.65$^{\circ}$. The analysis shows that: (1) DGC for B2B produces a coherence loss $<$7% for DGC phase RMS residuals $<$30$^{\circ}$. (2) B2B images using close calibrators ( $<$1.67$^{\circ}$ ) are superior to in-band images using distant ones ( $>$2.42$^{\circ}$ ). (3) For more distant calibrators, B2B is preferred if it provides a calibrator $\sim$2$^{\circ}$ closer than the best in-band calibrator. (4) Decreasing image coherence and poorer image quality occur with increasing phase calibrator separation angle because of uncertainties in the antenna positions and sub-optimal phase referencing. (5) To achieve $>$70% coherence for long-baseline (16 km) band 7 (289GHz) observations, calibrators should be within $\sim$4$^{\circ}$ of the target.

preprint2020arXiv

Characterizing the accuracy of ALMA linear-polarization mosaics

We characterize the accuracy of linear-polarization mosaics made using the Atacama Large Millimeter/submillimeter Array (ALMA). First, we observed the bright, highly linearly polarized blazar 3C 279 at Bands 3, 5, 6, and 7 (3 mm, 1.6 mm, 1.3 mm, and 0.87 mm, respectively). At each band, we measured the blazar&#39;s polarization on an 11$\times$11 grid of evenly-spaced offset pointings covering the full-width at half-maximum (FWHM) area of the primary beam. After applying calibration solutions derived from the on-axis pointing of 3C 279 to all of the on- and off-axis data, we find that the residual polarization errors across the primary beam are similar at all frequencies: the residual errors in linear polarization fraction $P_\textrm{frac}$ and polarization position angle $χ$ are $\lesssim$0.001 ($\lesssim$0.1% of Stokes $I$) and $\lesssim$1$^\circ$ near the center of the primary beam; the errors increase to $\sim$0.003-0.005 ($\sim$0.3-0.5% of Stokes $I$) and $\sim$1-5$^\circ$ near the FWHM as a result of the asymmetric beam patterns in the (linearly polarized) $Q$ and $U$ maps. We see the expected double-lobed &#34;beam squint&#34; pattern in the circular polarization (Stokes $V$) maps. Second, to test the polarization accuracy in a typical ALMA project, we performed observations of continuum linear polarization toward the Kleinmann-Low nebula in Orion (Orion-KL) using several mosaic patterns at Bands 3 and 6. We show that after mosaicking, the residual off-axis errors decrease as a result of overlapping multiple pointings. Finally, we compare the ALMA mosaics with an archival 1.3 mm CARMA polarization mosaic of Orion-KL and find good consistency in the polarization patterns.

preprint2020arXiv

The Explosion in Orion-KL as Seen by Mosaicking the Magnetic Field with ALMA

We present the first linear-polarization mosaicked observations performed by the Atacama Large Millimeter/submillimeter Array (ALMA). We mapped the Orion-KLeinmann-Low (Orion-KL) nebula using super-sampled mosaics at 3.1 and 1.3 mm as part of the ALMA Extension and Optimization of Capabilities (EOC) program. We derive the magnetic field morphology in the plane of the sky by assuming that dust grains are aligned with respect to the ambient magnetic field. At the center of the nebula, we find a quasi-radial magnetic field pattern that is aligned with the explosive CO outflow up to a radius of approximately 12 arc-seconds (~ 5000 au), beyond which the pattern smoothly transitions into a quasi-hourglass shape resembling the morphology seen in larger-scale observations by the James-Clerk-Maxwell Telescope (JCMT). We estimate an average magnetic field strength $\langle B\rangle = 9.4$ mG and a total magnetic energy of 2 x 10^45 ergs, which is three orders of magnitude less than the energy in the explosive CO outflow. We conclude that the field has been overwhelmed by the outflow and that a shock is propagating from the center of the nebula, where the shock front is seen in the magnetic field lines at a distance of ~ 5000 au from the explosion center.