Source author record

Edouard Monakhov

Edouard Monakhov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Disorder-induced ordering in gallium oxide polymorphs

Polymorphs are common in nature and can be stabilized by applying external pressure in materials. The pressure/strain can also be induced by the gradually accumulated radiation disorder. However, in semiconductors, the radiation disorder accumulation typically results in the amorphization instead of engaging polymorphism. By studying these phenomena in gallium oxide we found that the amorphization may be prominently suppressed by the monoclinic to orthorhombic phase transition. Utilizing this discovery, a highly oriented single-phase orthorhombic film on the top of the monoclinic gallium oxide substrate was fabricated. Exploring this system, a novel mode of a lateral polymorphic regrowth, not previously observed in solids, was detected. In combination, these data envisage a new direction of research on polymorphs in Ga2O3 and, potentially, for similar polymorphic families in other materials.

preprint2015arXiv

Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper.

preprint2012arXiv

Elemental distribution and oxygen deficiency of magnetron sputtered ITO films

The atomic structure and composition of non-interfacial ITO and ITO-Si interfaces were studied with Transmission Electron Microscopy (TEM) and X-ray Photoelectron Spectroscopy (XPS). The films were deposited by DC magnetron sputtering on mono-crystalline p-type (100) Si wafers. Both as deposited and heat treated films consisted of crystalline ITO. The ITO/Si interface showed a more complicated composition. A thin layer of SiO$_x$ was found at the ITO/Si interface together with In and Sn nanoclusters, as well as highly oxygen deficient regions, as observed by XPS. High energy electron exposure of this area crystallized the In nanoclusters and at the same time increased the SiO$_x$ interface layer thickness.