Researcher profile

E. Morteau

E. Morteau contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2012arXiv

Improvement of xenon purification system using a combination of a pulse tube refrigerator and a coaxial heat exchanger

We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in a highpressurized large-scale xenon storage with much less thermal losses.

preprint2011arXiv

A liquid xenon TPC for a medical imaging Compton telescope

A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique. With an ultra-low-noise front-end electronics, the energy deposit and resolution of 511 keV γ-ray as a function of drift electric field (E) is measured with high precision. 500 μm of z resolution is estimated by measuring the charge carriers drift velocity and time resolution.

preprint2011arXiv

Measurement of the transverse diffusion coefficient of charge in liquid xenon

Liquid xenon (LXe) is a very attractive material as a detection medium for ionization detectors due to its high density, high atomic number, and low energy required to produce electron-ion pairs. Therefore it has been used in several applications, like γ detection or direct detection of dark matter. Now Subatech is working on the R & D of LXe Compton telescope for 3γ medical imaging, which can make precise tridimensional localization of a (β+, γ) radioisotope emitter. The diffusion of charge carriers will directly affect the spatial resolution of LXe ionization signal. We will report how we measure the transverse diffusion coefficient for different electric field (0.5 ~ 1.2 kV/cm) by observing the spray of charge carriers on drift length varying until 12cm. With very-low-noise front-end electronics and complete Monte-Carlo simulation of the experiment, the values of transverse diffusion coefficient are measured precisely.

preprint2011arXiv

On the operation of a Micropattern Gaseous UV-Photomultiplier in Liquid-Xenon

Operation results are presented of a UV-sensitive gaseous photomultiplier (GPM) coupled through a MgF2 window to a liquid-xenon scintillator. It consisted of a reflective CsI photocathode deposited on top of a THick Gaseous Electron Multiplier (THGEM); further multiplication stages were either a second THGEM or a Parallel Ionization Multiplier (PIM) followed by a MICROMEsh GAseous Structure (MICROMEGAS). The GPM operated in gas-flow mode with non-condensable gas mixtures. Gains of 10^4 were measured with a CsI-coated double-THGEM detector in Ne/CH4 (95:5), Ne/CF4 (95:5) and Ne/CH4/CF4 (90:5:5), with soft X-rays at 173 K. Scintillation signals induced by alpha particles in liquid xenon were measured here for the first time with a double-THGEM GPM in He/CH4 (92.5:7.5) and a triple-structure THGEM/PIM/MICROMEGAS GPM in Ne/CH4 (90:10) with a fast-current preamplifier.