Source author record

É. M. Michaud

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
5topics
4close collaborators

Published work

3 publications

preprint2022arXiv

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3×105e/(3\times10^5), as well as the strongest limits for charge ≤e/160\leq e/160, with a minimum vertical intensity of 1.36×10−71.36\times10^{-7}\,cm−2^{-2}s−1^{-1}sr−1^{-1} at charge e/160e/160. These results apply over a wide range of LIP masses (5\,MeV/c2c^2 to 100\,TeV/c2c^2) and cover a wide range of βγβγ values (0.1 -- 10610^6), thus excluding non-relativistic LIPs with βγβγ as small as 0.1 for the first time.

preprint2021arXiv

Constraints on dark photons and axion-like particles from SuperCDMS Soudan

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/c2c^2 to 500 eV/c2c^2 for both candidates, excluding previously untested parameter space for masses below ~1 keV/c2c^2. For the kinetic mixing of dark photons, values below 10−1510^{-15} are reached for particle masses around 100 eV/c2c^2; for the axioelectric coupling of axion-like particles, values below 10−1210^{-12} are reached for particles with masses in the range of a few-hundred eV/c2c^2.

preprint2021arXiv

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σˉe\barσ_{e} is constrained for dark matter masses from 0.5--10410^{4} MeV/c2/c^{2}; in the mass range from 1.2--50 eV/c2/c^{2} the dark photon kinetic mixing parameter ε\varepsilon and the axioelectric coupling constant gaeg_{ae} are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are σˉe = 8.7×10−34\barσ_{e}\,=\,8.7\times10^{-34} cm2^{2}, ε = 3.3×10−14\varepsilon\,=\,3.3\times10^{-14}, and gae = 1.0×10−9g_{ae}\,=\,1.0\times10^{-9}.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.