Source author record

E. Huby

E. Huby appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

Laboratory characterization of FIRSTv2 photonic chip for the study of substellar companions

FIRST (Fibered Imager foR a Single Telescope instrument) is a post-AO instrument that enables high contrast imaging and spectroscopy at spatial scales below the diffraction limit. FIRST achieves sensitivity and accuracy by a unique combination of sparse aperture masking, spatial filtering by single-mode fibers and cross-dispersion in the visible. The telescope pupil is divided into sub-pupils by an array of microlenses, coupling the light into single-mode fibers. The output of the fibers are rearranged in a non redundant configuration, allowing the measurement of the complex visibility for every baseline over the 600-900 nm spectral range. A first version of this instrument is currently integrated to the Subaru Extreme AO bench (SCExAO). This paper focuses on the on-going instrument upgrades and testings, which aim at increasing the instrument's stability and sensitivity, thus improving the dynamic range. FIRSTv2's interferometric scheme is based on a photonic chip beam combiner. We report on the laboratory characterization of two different types of 5-input beam combiner with enhanced throughput. The interferometric recombination of each pair of sub-pupils is encoded on a single output. Thus, to sample the fringes we implemented a temporal phase modulation by pistoning the segmented mirrors of a Micro-ElectroMechanical System (MEMS). By coupling high angular resolution and spectral resolution in the visible, FIRST offers unique capabilities in the context of the detection and spectral characterization of close companions, especially on 30m-class telescopes.

preprint2020arXiv

SPHERE+: Imaging young Jupiters down to the snowline

SPHERE (Beuzit et al,. 2019) has now been in operation at the VLT for more than 5 years, demonstrating a high level of performance. SPHERE has produced outstanding results using a variety of operating modes, primarily in the field of direct imaging of exoplanetary systems, focusing on exoplanets as point sources and circumstellar disks as extended objects. The achievements obtained thus far with SPHERE (~200 refereed publications) in different areas (exoplanets, disks, solar system, stellar physics...) have motivated a large consortium to propose an even more ambitious set of science cases, and its corresponding technical implementation in the form of an upgrade. The SPHERE+ project capitalizes on the expertise and lessons learned from SPHERE to push high contrast imaging performance to its limits on the VLT 8m-telescope. The scientific program of SPHERE+ described in this document will open a new and compelling scientific window for the upcoming decade in strong synergy with ground-based facilities (VLT/I, ELT, ALMA, and SKA) and space missions (Gaia, JWST, PLATO and WFIRST). While SPHERE has sampled the outer parts of planetary systems beyond a few tens of AU, SPHERE+ will dig into the inner regions around stars to reveal and characterize by mean of spectroscopy the giant planet population down to the snow line. Building on SPHERE's scientific heritage and resounding success, SPHERE+ will be a dedicated survey instrument which will strengthen the leadership of ESO and the European community in the very competitive field of direct imaging of exoplanetary systems. With enhanced capabilities, it will enable an even broader diversity of science cases including the study of the solar system, the birth and death of stars and the exploration of the inner regions of active galactic nuclei.

preprint2016arXiv

A Mach-Zehnder interferometer based on orbital angular momentum for improved vortex coronagraph efficiency

The Annular Groove Phase Mask (AGPM) is a vectorial vortex phase mask. It acts as a half-wave plate with a radial fast axis orientation operating in the mid infrared domain. When placed at the focus of a telescope element provides a continuous helical phase ramp for an on axis sources, which creates the orbital angular momentum. Thanks to that phase, the intensity of the central source is canceled by a down-stream pupil stop, while the off axis sources are not affected. However due to experimental conditions the nulling is hardly perfect. To improve the null, a Mach-Zehnder interferometer containing Dove prisms differently oriented can be proposed to sort out light based on its orbital angular momentum (OAM). Thanks to the differential rotation of the beam, a π phase shift is achieved for the on axis light affected by a non zero OAM. Therefore the contrast between the star and its faint companion is enhanced. Nevertheless, due the Dove prisms birefringence, the performance of the interferometer is relatively poor. To solve this problem, we propose to add a birefringent wave-plate in each arm to compensate this birefringence. In this paper, we will develop the mathematical model of the wave front using the Jones formalism. The performance of the interferometer is at first computed for the simple version without the birefringent plate. Then the effect of the birefringent plate is be mathematically described and the performance is re-computed.

preprint2015arXiv

The Subaru Coronagraphic Extreme Adaptive Optics system: enabling high-contrast imaging on solar-system scales

The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is a multipurpose high-contrast imaging platform designed for the discovery and detailed characterization of exoplanetary systems and serves as a testbed for high-contrast imaging technologies for ELTs. It is a multi-band instrument which makes use of light from 600 to 2500nm allowing for coronagraphic direct exoplanet imaging of the inner 3 lambda/D from the stellar host. Wavefront sensing and control are key to the operation of SCExAO. A partial correction of low-order modes is provided by Subaru's facility adaptive optics system with the final correction, including high-order modes, implemented downstream by a combination of a visible pyramid wavefront sensor and a 2000-element deformable mirror. The well corrected NIR (y-K bands) wavefronts can then be injected into any of the available coronagraphs, including but not limited to the phase induced amplitude apodization and the vector vortex coronagraphs, both of which offer an inner working angle as low as 1 lambda/D. Non-common path, low-order aberrations are sensed with a coronagraphic low-order wavefront sensor in the infrared (IR). Low noise, high frame rate, NIR detectors allow for active speckle nulling and coherent differential imaging, while the HAWAII 2RG detector in the HiCIAO imager and/or the CHARIS integral field spectrograph (from mid 2016) can take deeper exposures and/or perform angular, spectral and polarimetric differential imaging. Science in the visible is provided by two interferometric modules: VAMPIRES and FIRST, which enable sub-diffraction limited imaging in the visible region with polarimetric and spectroscopic capabilities respectively. We describe the instrument in detail and present preliminary results both on-sky and in the laboratory.

preprint2013arXiv

FIRST, a fibered aperture masking instrument II. Spectroscopy of the Capella binary system at the diffraction limit

FIRST is a prototype instrument built to demonstrate the capabilities of the pupil remapping technique, using single-mode fibers and working at visible wavelengths. We report on observations of the binary system Capella at three epochs over a period of 14 months with FIRST-18 (that recombines 2 sets of 9 fibers) mounted on the 3-m Shane telescope at Lick Observatory. The binary separation during our observations ranges from 0.8 to 1.2 times the diffraction limit of the telescope at the central wavelength. We successfully resolved the Capella binary system with an astrometric precision as good as 1mas under the best observing conditions. FIRST also gives access to the spectral flux ratio between the two components directly measured with an unprecedented spectral resolution (around 300) over the 600-850nm range. In particular, our data allow to detect the well-known overall slope of the flux ratio spectrum, leading to an estimation of the pivot wavelength of 0.64+/-0.01um, at which the cooler component becomes the brightest. Spectral features arising from the difference in effective temperature (specifically the Halpha line, TiO and CN bands) have been used to constrain the stellar parameters. The effective temperatures we derive for both components are slightly lower (5-7%) than the well-established properties for this system. This difference mainly originates from deeper molecular features than those predicted by state-of-the-art stellar atmospheric models, suggesting that molecular line lists used in the photospheric models are incomplete and/or oscillator strengths are underestimated (most likely concerning the CN molecule). These results demonstrate the power of FIRST, a fibered pupil remapping based instrument, in terms of high angular resolution and show that the direct measurement of the spectral flux ratio provides valuable information to characterize little known companions.

preprint2012arXiv

FIRST, a fibered aperture masking instrument. I. First on-sky test results

In this paper we present the first on-sky results with the fibered aperture masking instrument FIRST. Its principle relies on the combination of spatial filtering and aperture masking using single-mode fibers, a novel technique that is aimed at high dynamic range imaging with high angular resolution. The prototype has been tested with the Shane 3-m telescope at Lick Observatory. The entrance pupil is divided into subpupils feeding single-mode fibers. The flux injection into the fibers is optimized by a segmented mirror. The beams are spectrally dispersed and recombined in a non-redundant exit configuration in order to retrieve all contrasts and phases independently. The instrument works at visible wavelengths between 600 nm and 760 nm and currently uses nine of the 30 43 cm subapertures constituting the full pupil. First fringes were obtained on Vega and Deneb. Stable closure phases were measured with standard deviations on the order of 1 degree. Closure phase precision can be further improved by addressing some of the remaining sources of systematic errors. While the number of fibers used in the experiment was too small to reliably estimate visibility amplitudes, we have measured closure amplitudes with a precision of 10 % in the best case. These first promising results obtained under real observing conditions validate the concept of the fibered aperture masking instrument and open the way for a new type of ground-based instrument working in the visible. The next steps of the development will be to improve the stability and the sensitivity of the instrument in order to achieve more accurate closure phase and visibility measurements, and to increase the number of sub-pupils to reach full pupil coverage.