Source author record

E. Baldelomar

E. Baldelomar appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2011arXiv

Application of Large Scale GEM for Digital Hadron Calorimetry

The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future International Linear Collider. In this study, two kinds of prototype GEM detectors have been tested. One has 30x30 cm2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap. The other one has two 2x2 cm2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. We present characteristics of these detectors obtained using high-energy charged particles, cosmic ray muons and 106Ru and 55Fe radioactive sources. From the 55Fe tests, we observed two well-separated X-ray emission peaks and measured the chamber gain to be over 6500 with a high voltage of 395 V across each GEM electrode. Both the spectra from cosmic rays and the 106Ru fit well to Landau distributions as expected from minimum ionizing particles. We also present the chamber performance after high dosage exposure to radiation as well as the pressure dependence of the gain and correction factors. Finally, we discuss the quality test results of the first set of large scale GEM foils and discuss progress and future plans for constructing large scale (100cmx100cm) GEM detectors.

preprint2011arXiv

Development of Large Area GEM Chambers

The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future International Linear Collider. In this study, two kinds of prototype GEM detectors have been tested. One has 30x30 cm2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap. The other one has two 2x2 cm2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. We present characteristics of these detectors obtained using high-energy charged particles, cosmic ray muons and 106Ru and 55Fe radioactive sources. From the 55Fe tests, we observed two well-separated X-ray emission peaks and measured the chamber gain to be over 6500 with a high voltage of 395 V across each GEM electrode. Both the spectra from cosmic rays and the 106Ru fit well to Landau distributions as expected from minimum ionizing particles. We also present the chamber performance after high dosage exposure to radiation as well as the pressure dependence of the gain and correction factors. Finally, we discuss the quality test results of the first set of large scale GEM foils and discuss progress and future plans for constructing large scale (100cmx100cm) GEM detectors.