Source author record

Dylan H. Mahler

Dylan H. Mahler appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2021arXiv

Mitigating linear optics imperfections via port allocation and compilation

Linear optics is a promising route to building quantum technologies that operate at room temperature and can be manufactured scalably on integrated photonic platforms. However, scaling up linear optics requires high-performance operation amid inevitable manufacturing imperfections. We present techniques for enhancing the performance of linear optical interferometers by tailoring their port allocation and compilation to the on-chip imperfections, which can be determined beforehand by suitable calibration procedures that we introduce. As representative examples, we demonstrate dramatic reductions in the average power consumption of a given interferometer or in the range of its power consumption values across all possible unitary transformations implemented on it. Furthermore, we demonstrate the efficacy of these techniques at improving the fidelities of the desired transformations in the presence of fabrication defects. By improving the performance of linear optical interferometers in relevant metrics by several orders of magnitude, these tools bring optical technologies closer to demonstrating true quantum advantage.

preprint2014arXiv

Characterizing an Entangled-Photon Source with Classical Detectors and Measurements

Quantum state tomography (QST) is a universal tool for the design and optimization of entangled-photon sources. It typically requires single-photon detectors and coincidence measurements. Recently, it was suggested that the information provided by the QST of photon pairs generated by spontaneous parametric down-conversion could be obtained by exploiting the stimulated version of this process, namely difference frequency generation. In this protocol, so-called "stimulated-emission tomography" (SET), a seed field is injected along with the pump pulse, and the resulting stimulated emission is measured. Since the intensity of the stimulated field can be several orders of magnitude larger than the intensity of the corresponding spontaneous emission, measurements can be made with simple classical detectors. Here, we experimentally demonstrate SET and compare it with QST. We show that one can accurately reconstruct the polarization density matrix, and predict the purity and concurrence of the polarization state of photon pairs without performing any single-photon measurements.

preprint2014arXiv

On the Optimal Choice of Spin-Squeezed States for Detecting and Characterizing a Quantum Process

Quantum metrology uses quantum states with no classical counterpart to measure a physical quantity with extraordinary sensitivity or precision. Most metrology schemes measure a single parameter of a dynamical process by probing it with a specially designed quantum state. The success of such a scheme usually relies on the process belonging to a particular one-parameter family. If this assumption is violated, or if the goal is to measure more than one parameter, a different quantum state may perform better. In the most extreme case, we know nothing about the process and wish to learn everything. This requires quantum process tomography, which demands an informationally-complete set of probe states. It is very convenient if this set is group-covariant -- i.e., each element is generated by applying an element of the quantum system's natural symmetry group to a single fixed fiducial state. In this paper, we consider metrology with 2-photon ("biphoton") states, and report experimental studies of different states' sensitivity to small, unknown collective SU(2) rotations ("SU(2) jitter"). Maximally entangled N00N states are the most sensitive detectors of such a rotation, yet they are also among the worst at fully characterizing an a-priori unknown process. We identify (and confirm experimentally) the best SU(2)-covariant set for process tomography; these states are all less entangled than the N00N state, and are characterized by the fact that they form a 2-design.

preprint2014arXiv

Quantum Data Compression of a Qubit Ensemble

Data compression is a ubiquitous aspect of modern information technology, and the advent of quantum information raises the question of what types of compression are feasible for quantum data, where it is especially relevant given the extreme difficulty involved in creating reliable quantum memories. We present a protocol in which an ensemble of quantum bits (qubits) can in principle be perfectly compressed into exponentially fewer qubits. We then experimentally implement our algorithm, compressing three photonic qubits into two. This protocol sheds light on the subtle differences between quantum and classical information. Furthermore, since data compression stores all of the available information about the quantum state in fewer physical qubits, it could provide a vast reduction in the amount of quantum memory required to store a quantum ensemble, making even today's limited quantum memories far more powerful than previously recognized.

preprint2013arXiv

A Note on Different Definitions of Momentum Disturbance

In [1], Busch et al. showed that it is possible to construct an error-disturbance relation having the same form as Heisenberg's original heuristic definition[2], in contrast to the theory proposed by Ozawa[3] which we and others recently confirmed experimentally[4,5]. With Ozawa's definitions of measurement error and disturbance, a relation of Heisenberg's form is not in general valid, and a new error-disturbance relationship can be derived. Here we explain the different physical significance of the two definitions, and suggest that Ozawa's definition better corresponds to the usual understanding of the disturbance that Heisenberg discussed.

preprint2013arXiv

Scalable Spatial Super-Resolution using Entangled Photons

N00N states -- maximally path-entangled states of N photons -- exhibit spatial interference patterns sharper than any classical interference pattern. This is known as super-resolution. However, even with perfectly efficient number-resolving detectors, the detection efficiency of all previously demonstrated methods to measure such interference decreases exponentially with the number of photons in the N00N state, often leading to the conclusion that N00N states are unsuitable for spatial measurements. Here, we create spatial super-resolution fringes with two-, three-, and four-photon N00N states, and demonstrate a scalable implementation of the so-called ``optical centroid measurement'' which provides an in-principle perfect detection efficiency. Moreover, we compare the N00N-state interference to the corresponding classical super-resolution interference. Although both provide the same increase in spatial frequency, the visibility of the classical fringes decreases exponentially with the number of detected photons, while the visibility of our experimentally measured N00N-state super-resolution fringes remains approximately constant with N. Our implementation of the optical centroid measurement is a scalable method to measure high photon-number quantum interference, an essential step forward for quantum-enhanced measurements, overcoming what was believed to be a fundamental challenge to quantum metrology.

preprint2012arXiv

Self-calibrating Quantum State Tomography

We introduce and experimentally demonstrate a technique for performing quantum state tomography on multiple-qubit states despite incomplete knowledge about the unitary operations used to change the measurement basis. Given unitary operations with unknown rotation angles, our method can be used to reconstruct the density matrix of the state up to local sigma-z rotations as well as recover the magnitude of the unknown rotation angle. We demonstrate high-fidelity self-calibrating tomography on polarization-encoded one- and two-photon states. The unknown unitary operations are realized in two ways: using a birefringent polymer sheet---an inexpensive smartphone screen protector---or alternatively a liquid crystal wave plate with a tuneable retardance. We explore how our technique may be adapted for quantum state tomography of systems such as biological molecules where the magnitude and orientation of the transition dipole moment is not known with high accuracy.

preprint2012arXiv

Violation of Heisenberg's Measurement-Disturbance Relationship by Weak Measurements

While there is a rigorously proven relationship about uncertainties intrinsic to any quantum system, often referred to as "Heisenberg's Uncertainty Principle," Heisenberg originally formulated his ideas in terms of a relationship between the precision of a measurement and the disturbance it must create. Although this latter relationship is not rigorously proven, it is commonly believed (and taught) as an aspect of the broader uncertainty principle. Here, we experimentally observe a violation of Heisenberg's "measurement-disturbance relationship", using weak measurements to characterize a quantum system before and after it interacts with a measurement apparatus. Our experiment implements a 2010 proposal of Lund and Wiseman to confirm a revised measurement-disturbance relationship derived by Ozawa in 2003. Its results have broad implications for the foundations of quantum mechanics and for practical issues in quantum mechanics.