Source author record

Donald B. Conkey

Donald B. Conkey appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Real-time resilient focusing through a bending multimode fiber

We introduce a system capable of focusing light through a multimode fiber in 37ms, one order of magnitude faster than demonstrated in previous reports. As a result, the focus spot can be maintained during significant bending of the fiber, opening numerous opportunities for endoscopic imaging and energy delivery applications. We measure the transmission matrix of the fiber by projecting binary-amplitude computer generated holograms using a digital micromirror device and a field programmable gate array controller. The system shows two orders of magnitude enhancements of the focus spot relative to the background.

preprint2013arXiv

Super-resolution photoacoustic imaging through a scattering wall

Imaging through opaque, highly scattering walls is a long sought after capability with potential applications in a variety of fields. The use of wavefront shaping to compensate for scattering has brought a renewed interest as a potential solution to this problem. A key to the practicality of any imaging technique is the capability to focus light without direct access behind the scattering wall. Here, we address this problem using photoacoustic feedback for wavefront optimization. By combining the spatially non-uniform sensitivity of the ultrasound transducer to the generated photoacoustic waves with an evolutionary competition among optical modes, the speckle field develops a single, high intensity focus significantly smaller than the acoustic focus used for feedback. Notably, this method is not limited by the size of the absorber to form a sub-acoustic optical focus. We demonstrate imaging behind a scattering medium with up to ten times improvement in signal-to-noise ratio (SNR) and five to six times sub-acoustic resolution. The results presented here open up opportunities for 3D imaging applications in the diffusive regime beyond the sound wave diffraction-limited resolution, including medical imaging, photothermal therapy, neuroscience, and optogenetics.